Connection to LA amplied controllers
Connection to LA amplied controllers
Enclosure drive capacity per amplied controller
Make sure the total number of connected enclosures does not exceed the maximum number of enclosures per controller
(refer to the footnotes).
LA4X
LA8
LA12X
per output
/
total
per output
/
total
per output
/
total
K2
1 / 1
3 / 3
3 / 3
Kara
2 / 4
3 / 6
3 / 6
K1-SB
-
1 / 4
1 / 4
KS28
-
-
1 / 4
SB28
-
1 / 4
1 / 4
Cabling scheme for K2
Refer to the cabling schemes to connect the enclosures to different types of output connectors.
L-Acoustics does not supply the speakON-to-PA-COM interface.
It must be built with two 4-point speakON connectors and a female 8-point PA-COM connector (no cable clamp).
Four-channel CA-COM output
DO
DO
2 × Two-channel speakON output
1+/1-
2+/2-
1+/1-
2+/2-
custom speakON to CA-COM
*
For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output. For active
loudspeakers, the value corresponds to the number of sections in parallel on the output.
K2 owner's manual (EN) version 1.1