Corrective maintenance
D/R - HF diaphragm
Tools
• torque screwdriver
• T20 Torx bit
• 3 mm hex bit
• compressed air blower
Repair kit
G03520
KR diaphragm for 3" driver Kara II(i)
×1
×4
17581
S100082
diaphragm assembly (with 2 shims)
M4×14 hex
Prerequisite
Connector plate removed.
See
(p.110).
HF driver removed from the cabinet.
See
(p.111).
The driver is placed on a at surface in a dust-free
environment.
Disassembly
Procedure
1.
Remove the four screws securing the cover.
Use the T20 Torx bit.
2.
Remove the cover.
3.
Carefully remove the diaphragm.
4.
If there are shims on the dome, carefully remove them.
Take note of how many and what kind of shims are present.
112
Kara IIi owner's manual (EN) version 2.0