Loudspeaker connection
Connection to LA8
Maximum number of enclosures per LA8
enclosure
max enclosures in parallel
max enclosures per controller
Kiva II
4
16
SB15m
2
6
SB18
2
8
Make sure the total number of connected enclosures does not exceed the maximum number
of enclosures per controller.
LA8 can drive up to two SB15m per output, but no more than six per controller at high level.
Impedance load
SB15m SB18
1 enclosure: 8 Ω
2 enclosures in parallel: 4 Ω
Kiva II
1 enclosure: 16 Ω
2 enclosures in parallel: 8 Ω
3 enclosures in parallel: 5.3 Ω
4 enclosures in parallel: 4 Ω
Connection to LA12X
Maximum number of enclosures per LA12X
enclosure
max enclosures in parallel
max enclosures per controller
Kiva II
6
24
SB15m
3
12
SB18
3
12
Impedance load
SB15m SB18
1 enclosure: 8 Ω
2 enclosures in parallel: 4 Ω
3 enclosures in parallel: 2.7 Ω
Kiva II
1 enclosure: 16 Ω
2 enclosures in parallel: 8 Ω
3 enclosures in parallel: 5.3 Ω
4 enclosures in parallel: 4 Ω
5 enclosures in parallel: 3.2 Ω
6 enclosures in parallel: 2.7 Ω
Kiva II owner's manual (EN) version 1.0