Mechanical safety
Mechanical safety
Flown congurations
The Kiva II rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the
guidelines of BGV-C1.
2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described in
this manual achieve a safety factor of
4 or higher
.
Refer to Soundvision for the safety factor of a specic deployment.
The
safe limit
gives the maximum number of elements for which the safety factor is compliant with the 2006/42/
EC: Machinery Directive, within the use dened in this manual and regardless of the other deployment parameters (site
angles, inter-enclosure angles, etc.).
The
maximum limit
gives the maximum number of elements for which the safety factor can be compliant with the
2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.
For mixed arrays refer to your Soundvision model.
Kiva II
conguration
rigging accessory
safe limit
maximum limit
own
KIBU-SB
8
20
own
KIBU II
8
20
pullback
KIBU II / KIBU-SB + KIVA-PULLBACK
9
ceiling-mounted
KIET II
3
SB15m
conguration
rigging accessory
maximum / Safe limit
own
KIBU-SB
8
Kiva II + SB15m
conguration
rigging accessory
maximum / safe limit
pullback
KIBU-SB + KIVA-PULLBACK
9 Kiva II + 3 SB15m
Other congurations
For other congurations, respect the recommended maximum limit for optimal stability.
Kiva II
conguration
rigging accessory
safe limit
maximum limit
stacked
KIBU-SB
4
9
pole-mounted
KIET II + 35 mm pole
3
pole-mounted
KIET II + 35 mm pole + SB15m
2
SB15m
conguration
rigging accessory
maximum / safe limit
ground-stacked
no rigging accessory
4
24
Kiva II owner's manual (EN) version 1.0