background image

 

 

 

 
 

 

 

 

 

 

 

KIVA-SB15

m

_RM_EN_1.1 

w w w . l - a c o u s t i c s . c o m  

19

 

 

APPENDIX B

 

SPECIFICATIONS 

KIVA 

Description 

2-way passive enclosure, amplified by LA4 or LA8 

Usable bandwidth (-10 dB) 

80 Hz - 20 kHz  ([KIVA] preset) 

Maximum SPL

1

 

130 dB ([KIVA] preset) 

Coverage angle (-6 dB) 
  

Horizontal: 100° (from 500 Hz) 
Vertical: depends on the number of elements and array curvature 

Transducers 

LF: 2 

 6.5", weather-resistant, bass-reflex 

HF: 1 

 1.5", diaphragm compression driver, DOSC

®

 waveguide 

Nominal impedance 

8 Ω 

RMS power handling 

120 W 

Connectors 

IN: 1 

 4-point SpeakON

®

 

LINK: 1 

 4-point SpeakON

®

 

Rigging components 

Captive 3-point rigging system 
Inter-enclosure angles: 0, 1, 2, 3, 4, 5, 7.5, 10, 12.5 or 15° 

Dimensions 

 

Physical data 

Weight (net): 

13 kg / 28.7 lb 

Cabinet: 

Back plate: 

Composite sandwich structure 

ZAMAC 

Finish: 

Grey brown, RAL 8019

® 

or Pure white  RAL 9010

® 

Custom RAL code on special order 

Front: 

Plastic grill 

Airnet

®

 acoustically neutral fabric 

Rigging components: 

High strength steel with anti-corrosion coating 

1

 Peak level at 1 m under free field conditions using 10 dB crest factor pink noise with specified preset. 

 
 

 

Summary of Contents for KIVA SB15M

Page 1: ...KIVA SYSTEM KIVA SB15m RIGGING MANUAL VERSION 1 1 www l acoustics com...

Page 2: ...the warnings in Mechanical Data section 9 Be cautious when flying a loudspeaker array Always verify that no one is standing underneath the loudspeaker array when it is being raised As the array is be...

Page 3: ...If the product requires repair or for information about the warranty please contact an approved L ACOUSTICS distributor The address of the nearest distributor is available on the L ACOUSTICS web site...

Page 4: ...ded with two SB15MRIG coupling bars equipped with the LOCKTAB locking tab 1 2 Rigging elements KIBU SB Frame for flying KIVA and SB15m enclosures as line elements or independent mixed arrays Provided...

Page 5: ...SB15m_RM_EN_1 1 w w w l a c o u s t i c s c o m 5 KIVA SB15m KIBU SB CLAMP250 SB15MRIG equipped with LOCKTAB Delivered with the SB15m KIET SOUNDVISION Main components involved in the KIVA rigging pro...

Page 6: ...to determine the maximum number of enclosures within an array or to assess the safety of a specific array configuration Mechanical modeling with SOUNDVISION The working load applied to each linking po...

Page 7: ...u s t i c s c o m 7 3 SYSTEM SETUP The KIVA SB15m rigging system relies on the use of KIBU SB as an interface between the two enclosures rigging systems Each side of KIBU SB is compatible with one en...

Page 8: ...op Refer to PROCEDURE B Repeat the previous step until the array is completed Risk of fall Do not climb on a loudspeaker array KIVA SB15m Place one SB15m logo down on the ground If necessary place and...

Page 9: ...up Refer to PROCEDURE A Attach a bow shackle WLL 1 t or a CLAMP250 on the KIBU SB Refer to PROCEDURE B If more than one SB15m is needed raise the array so you can position another SB15m under it Lower...

Page 10: ...re on the ground logo on the left hand side and attach a second enclosure to it Refer to PROCEDURE B Assemble the KIET and the pole adapter and attach the assembly on the KIVA enclosure s Refer to PRO...

Page 11: ...ar by pushing it into place b Pinch the spring tongue and slide the locking tab until it snaps into place When encountering difficulty try to slide the tab from the other side c Verify that the yellow...

Page 12: ...of available angles varies depending of the rigging position front position 0 1 2 rear position 7 5 5 2 5 0 2 5 3 5 4 5 5 5 6 5 7 5 Refer to Figure 1 to choose the hole corresponding to the targeted s...

Page 13: ...the second element using the appropriate hole for your configuration a On the enclosure pull the spring loaded pin to release the angulation arm b If you are attaching two enclosures together i Pull t...

Page 14: ...5m rigging manual VERSION 1 1 KIVA SB15m_RM_EN_1 1 w w w l a c o u s t i c s c o m 14 3 a Releasing the angulation arm Attaching the angulation arm of a KIVA to KIVA 3 b Attaching the angulation arm o...

Page 15: ...umbering on the side of the SB15m KIBU SB hole numbering on the side of the KIVA 2 Attach a shackle or a CLAMP250 to the identified hole by driving the pierced bolt 3 Secure the pierced bolt with the...

Page 16: ...points at the front of the KIET to the two linking points of the enclosure a Place the KIVA enclosure with its logo on the right on a stable horizontal surface b Align the KIET linking points slightly...

Page 17: ...IVA SB15m_RM_EN_1 1 w w w l a c o u s t i c s c o m 17 PROCEDURE D 1 Assembling the KIET and its pole adapter 2 Attaching the KIET and the enclosure 3 Securing the enclosure angulation arm on the KIET...

Page 18: ...tor T20 Torx bit 7 mm hex key 1 Put the KIBU SB with its SB15m side up 2 Undo the four Torx bolts on the laser support plate Use a T20 bit and a 7 mm hex key 3 Place the LAP TEQ on the support plate w...

Page 19: ...C waveguide Nominal impedance 8 RMS power handling 120 W Connectors IN 1 4 point SpeakON LINK 1 4 point SpeakON Rigging components Captive 3 point rigging system Inter enclosure angles 0 1 2 3 4 5 7 5...

Page 20: ...4 point SpeakON LINK 1 4 point SpeakON Rigging components Integrated pole mount socket Coupling bars stored at handle position Dimensions Physical data Weight net 36 kg 79 4 lb Cabinet Baltic birch p...

Reviews: