Dismantling an array 

Apply the associated set-up procedure in reversed order. 

 
 
 

 

Independent or mixed 

 

This document only deals with independent rigging of the SB18m subwoofer enclosure. 
When using the SB18m enclosure as a companion to a main system, some combined configurations will imply 
the  set-up  of  mixed  arrays.  At  this  point,  it  is  especially  the  case  of  ARCS

®

WIDE/SB18m  or 

ARCS

®

FOCUS/SB18m  arrays.  Always  refer  to  the  rigging  manual  of  the  main  system  or  enclosure  to  get 

acquainted with the rigging procedures specific to the mixed main/sub arrays.  

 

 

Cardioid configuration 

The cardioid configuration is an array of 4 subwoofers with 1 reversed element.  
Refer to the subwoofer 

user manual 

for details about the CARDIOID operating mode.  

Any of the following arrangements can be set in cardioid configuration. 

 
 
 
 

3.1

 

Ground-stacking 

 

Vertical stacked on SB18m 

 

 

 

 Attach the enclosures one after the other, on top of each other (logo down)

 

 

Refer to PROCEDURE 

to lock the SB18MRIG bars

 

 

 

 

 

Block 

 

 

 

 Set vertical stacks, side by side, one after the other, by attaching  the 

enclosures on top of each other (logo down) 

  

Refer to PROCEDURE

 A 

to lock the SB18MRIG bars

 

 

 
 
 

Horizontal & On-end 

 

 

 

 

 

 

 

 

Place the enclosures side by side

 

 

 

 
 

Summary of Contents for KIVA SB18m

Page 1: ...SB18 SB18 SB18 SB18m SUBWOOFER SUBWOOFER SUBWOOFER SUBWOOFER RIGGING MANUAL RIGGING MANUAL RIGGING MANUAL RIGGING MANUAL VERSION 1 0 www l acoustics com ...

Page 2: ...e suspension points chain hoists and all additional hardware rigging accessories is respected 8 Respect the maximum configurations and the recommended safety level For safety issue respect the maximum configurations outlined in this manual To check the conformity of any configuration in regards with the safety level recommended by L ACOUSTICS model the system in SOUNDVISION and refer to the warnin...

Page 3: ...L L ACOUSTICS ACOUSTICS ACOUSTICS ACOUSTICS Thank you for choosing the L ACOUSTICS SB18m subwoofer This document contains essential information on rigging the system properly and safely Carefully read this document in order to become familiar with these procedures As part of a continuous evolution of techniques and standards L ACOUSTICS reserves the right to change the specifications of its produc...

Page 4: ...les amplified controllers and software applications The SB18m subwoofer is especially adapted to the ARCS WIDE SYSTEM or ARCS FOCUS SYSTEM and to the coaxial XT enclosures from L ACOUSTICS It extends the low frequency response of a loudspeaker system down to 32Hz The main components involved in the SB18m rigging process are the following 1 1 Loudspeaker enclosure SB18m Subwoofer enclosure provided...

Page 5: ...ARCSWIFO_RM_EN_1 0 w w w l a c o u s t i c s c o m 5 5 5 5 Elements involved in the SB18m rigging process WIFOBUMP SB18m SOUNDVISION CLAMP250 SB18COV SB18PLA ...

Page 6: ...e to determine the maximum number of enclosures within an array or to assess the safety of a specific array configuration Mechanical modeling with SOUNDVISION The working load applied to each linking point along with the corresponding safety factor will depend on numerous variables linked to the composition of the array type and number of enclosures splay angles and the implementation of the flyin...

Page 7: ...l of the main system or enclosure to get acquainted with the rigging procedures specific to the mixed main sub arrays Cardioid configuration The cardioid configuration is an array of 4 subwoofers with 1 reversed element Refer to the subwoofer user manual for details about the CARDIOID operating mode Any of the following arrangements can be set in cardioid configuration 3 1 Ground stacking Vertical...

Page 8: ...by modeling the system in SOUNDVISION Vertical Place the first enclosure logo down Place and lock a second SB18m on top of the first one logo down Refer to PROCEDURE A to lock the SB18MRIG bars Remove the coupling bars from their storage location Place and lock the WIFOBUMP frame to the top enclosure Refer to SOUNDVISION for the frame position front or rear Refer to PROCEDURE A to lock the SB18MRI...

Page 9: ...ing rails from the front of the array STORAGE Engage the bar into both storage pins Secure the bar with the locking tab a Accurately position the bar by pushing it into place b Pinch the spring tongue and slide the locking tab until it snaps into place When encountering difficulty try to slide the tab from the other side PROCEDURE A Locking a rigging bar SB18MRIG bars being slid into adjacent RIGG...

Page 10: ... About site angle As many variables can affect the actual site angle it is recommended to use an inclinometer Secure a shackle or CLAMP250 to the identified hole a Attach the shackle or the CLAMP250 bar to the identified hole by driving the pierced bolt and securing the nut b Lock the pierced bolt with the safety pin c With CLAMP250 install safety slings between the WIFOBUMP and the truss PROCEDUR...

Page 11: ...ARCSWIFO_RM_EN_1 0 w w w l a c o u s t i c s c o m 11 11 11 11 ...

Page 12: ...ence SB18m_RM_EN_1 0 Distribution date September 25 2012 2012 L ACOUSTICS All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express written consent of the publisher ...