KUDO
®
MULTI-MODE WST
®
SYSTEM
Rigging Procedures
VERSION 1.0
KUDO_RM_ML_1.0
w w w . l - a c o u s t i c s . c o m
30 en
9.2
KLIFT site angle setting
When flying a horizontal KUDO
®
array underneath one or two KLIFT rigging accessories, the site angle is set by
securing the 18-shackle into one of the 12 pick point holes numbered below:
Figure 42
: KLIFT hole numbering convention
The site angles corresponding to pick point holes are given in the following chart for two or three KUDO
®
enclosures:
Table 1: Pick point holes numbers and corresponding angles
Pick Point Hole Number
Site angle for 2 KUDO
®
(1 KLIFT)
Site angle for 3 KUDO
®
(2 KLIFT)
1
+12.8 °
+14.3 °
2
+8.3 °
+9.8 °
3
+3.6 °
+5.2 °
4
-1 °
-0.5 °
5
-5.7 °
-4.2 °
6
-10.3 °
-8.8 °
7
-14.8 °
-13.3 °
8
-19.1 °
-17.7 °
9
-23.2 °
-21.8 °
10
-27 °
-25.8 °
11
-30.6 °
-29.5 °
12
-34 °
-32.9 °
Note:
Please refer to SOUNDVISION calculations for larger horizontal KUDO
®
array configurations (Figure 43).
Always refer to the mechanical data and warning indications provided in SOUNDVISION to verify
that safe system setup safety limits apply (see section ‘‘Mechanical Data’’ in the SOUNDVISION
software).
Figure 43
:
Two to seven-KUDO
®
horizontal arrays with KLIFT accessories
1
2
3
4
5
6
7
9
10
11
12
Front
Rear
Serial
number
plate
!
WARNING