Maintenance
L-NET network issues
impossible to connect a controller to the L-NET network (controller not in “grey screen”)
Refer to the LA Network Manager video tutorial for software use.
possible cause
diagnosis / procedure
LA Network Manager is set in ofine mode
select the online mode
selected scanning range does not contain the amplied
controller IP address
include the amplied controller IP address into the
scanning range
amplied controller is set with an incorrect IP address,
or several amplied controller are set with the same IP
address
set the computer IP address and subnet mask and the
amplied controller IP address as indicated in the LA
Network Manager video tutorial
L-NET cable is not plugged or incorrectly plugged
plug and secure CAT5e U/FTP cables into the L-NET
connectors on the amplied controllers to connect it to the
other amplied controllers, the computer or to the Ethernet
switch
(each of the amplied controller connectors can be equally
used as an IN or LINK connector).
The ACT/LINK LEDs should turn on.
Refer to the LA Network Manager video tutorial.
L-NET cable is damaged
replace all damaged CAT5e U/FTP cables in the network
chain
more than two software clients are already connected to
the amplied controller
disconnect all other software clients
rmware failure
restart the amplied controller
other causes
contact L-Acoustics
59
LA12X user manual (en) version 2.0
Summary of Contents for LA12X
Page 1: ...LA12X user manual en...
Page 5: ...Latency 70 Remote control and monitoring 70 Physical data 70 Approvals 71 5...
Page 16: ...Installation Refer to the LA RAK II user manual LA12X user manual en version 2 0 16...
Page 71: ...Approvals Approvals 71 LA12X user manual en version 2 0...
Page 72: ......