Important safety instructions

Explanation of graphical symbols

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user

to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of

sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of

important operating and maintenance instructions in the literature accompanying the product.

1.

Read these instructions.

2.

Keep these instructions.

3.

Heed all warnings.

4.

Follow all instructions.

5.

Do not use this apparatus near water.

6.

Clean only with dry cloth.

7.

Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.

8.

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus

(including amplifiers) that produce heat.

9.

Do not defeat the safety purpose of the grounding-type plug. A grounding-type plug has two blades

and a third grounding prong. The third prong is provided for your safety. If the provided plug does not

fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.

Protect the power cord from being walked on or pinched particularly at plugs, convenience

receptacles, and the point where they exit from the apparatus.

11.

Only use attachments/accessories specified by the manufacturer.

12.

Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the

apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid

injury from tip-over.

13.

Unplug this apparatus during lightning storms or when unused for long periods of time.

14.

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or

objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not

operate normally, or has been dropped.

15.

WARNING: To reduce the risk of fire or electric shock, this apparatus should not be exposed to rain

or moisture and objects filled with liquids, such as vases, should not be placed on this apparatus.

Summary of Contents for LA12X

Page 1: ...LA12X product information PRODUCT SERIAL NUMBER ___________________________________...

Page 2: ...nformation version 1 0 Distribution date April 21 2016 2016 L Acoustics All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express...

Page 3: ...ype plug has two blades and a third grounding prong The third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolet...

Page 4: ...s 100 120 V 30 A 200 240 V 16 A Electrical generator You must power on the generator before powering on the product Verify that the product is turned off before powering on the generator Terminals mar...

Page 5: ...em Strictly follow the installation and operating instructions Read the maintenance section of this document before servicing the product Shipping Use the original packaging for shipping the product u...

Page 6: ...rton and packing materials to be inspected by the carrier Carefully read this document in order to become familiar with the product and to identify the external documents containing essential informat...

Page 7: ...ation at 1 kHz 3 x 120 W 4 85 dB damping factor 400 1 kHz and below 8 output delay 0 ms to 1000 ms mains input power and current draw all channels driven maximum output power 4 x 1400 W RMS at 8 4 x 2...

Page 8: ...terface 2 x 24 characters LCD screen output connectors 2 x 4 point speakON 1 x 8 point CA COM L NET connectors 2 x 1 Gb s Ethernet etherCON Input Signal distribution connectors input 4 Neutrik female...

Page 9: ...l clock at 96 kHz Sample Rate Converter SRC sampling frequency 96 kHz SRC referenced to the amplified controller internal clock word length 24 bits dynamic range 140 dB distortion THD N 120 dBfs bandp...

Page 10: ...Network Manager 2 third party management solutions SNMP Extron Crestron Extron is a registered trademark of Extron Electronics Crestron is a trademark or registered trademark of Crestron Electronics...

Page 11: ...le dispositif de s curit de la prise de type terre Une prise de type terre est constitu e de deux contacts m les et d un contact femelle pour la connexion la terre Le contact femelle assure la s curi...

Page 12: ...er de reproduire un circuit 200 V en connectant l appareil deux phases d un circuit triphas 100 V Interconnectez syst matiquement un disjoncteur de classe C entre l appareil et le secteur L amp rage d...

Page 13: ...t 50 C 122 F N exposez pas l appareil au soleil Utilisez l appareil uniquement dans un environnement lectromagn tique conforme Les environnements conformes sont sp cifi s dans le standard EN55103 2 po...

Page 14: ...nsable assurant l installation ou l exploitation du produit en toute s curit Ce symbole signale un risque d accident lectrique Il peut galement signaler une instruction indispensable assurant l instal...

Page 15: ...soci t de transport ou le distributeur Seul le destinataire peut faire r clamation pour tout dommage occasionn pendant le transport Conservez le carton et les pi ces d emballage pour constatation de...

Page 16: ...s paration de canaux 1 kHz 3 x 120 W 4 85 dB facteur d amortissement 400 1 kHz et en dessous 8 d lai de sortie 0 ms 1000 ms Consommation de puissance et de courant tous canaux aliment s puissance de s...

Page 17: ...r le courant le statut et L NET pour chaque sortie 7 x LEDs pour informer sur le mute la charge le signal les niveaux et le limiteur cr tage interface cran LCD 2 x 24 caract res connecteurs de sortie...

Page 18: ...bits synchronisation signal re r f renc l horloge interne 96 kHz convertisseur de fr quence d chantillonnage SRC fr quence d chantillonnage 96 kHz SRC r f renc l horloge interne du contr leur r soluti...

Page 19: ...e gestion tierces SNMP Extron Crestron Extron est une marque d pos e de Extron Electronics Crestron est une marque ou marque d pos e de Crestron Electronics Inc aux tats Unis et ou dans d autres pays...

Page 20: ...Notes LA12X product information version 1 0 20 Notes...

Page 21: ...Notes 21 LA12X product information version 1 0...

Page 22: ...Notes LA12X product information version 1 0 22...

Page 23: ......

Page 24: ......

Reviews: