background image

[EN] Safety

5

 LA12X product information version 1.0

Inspect the product before operation.

If any sign of defect or damage is detected, immediately withdraw the product from use for maintenance.

This product is intended for use by trained personnel.

Do not use the product outside its operating temperature range.

The product operates at a room temperature between 0° C / 32° F and 50° C / 122° F.
Do not expose the product to direct sun.

Only use the product in a conformed electro-magnetic environment.

Conformed environments are specified in EN55103-2 standards as E1 (residential), E2 (commercial and light

industrial), E3 (urban outdoors), and E4 (controlled EMC environment, ex. TV studio).

Avoid radio interference.

This product has been tested and complies with the limits indicated in the EMC directive (Electro Magnetic

Compatibility). These limits are designed to provide reasonable protection against harmful interference from

electrical equipment, but it cannot be guaranteed that interference will never occur.

Read the USER MANUAL before operating the system.

Strictly follow the installation and operating instructions.

Read the maintenance section of this document before servicing the product.

Shipping

Use the original packaging for shipping the product, unless it is mounted in a rack with the front and rear panels

fixed to the rack, as described in the USER MANUAL.

Maintain this document as an integral part of the product.

Keep this document in a safe place.
Record in this document any maintenance operation performed on the product.
Do not resell the product without this updated document.

Symbols

The following symbols are used in this document:

This symbol indicates a potential risk of harm to an individual or damage to the product.
It can also notify the user about instructions that must be strictly followed to ensure safe installation or operation of

the product.

This symbol indicates a potential risk of electrical injury.
It can also notify the user about instructions that must be strictly followed to ensure safe installation or operation of

the product.

This symbol notifies the user about instructions that must be strictly followed to ensure proper installation or

operation of the product.

This symbol notifies the user about complementary information or optional instructions.

Summary of Contents for LA12X

Page 1: ...LA12X product information PRODUCT SERIAL NUMBER ___________________________________...

Page 2: ...nformation version 1 0 Distribution date April 21 2016 2016 L Acoustics All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express...

Page 3: ...ype plug has two blades and a third grounding prong The third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolet...

Page 4: ...s 100 120 V 30 A 200 240 V 16 A Electrical generator You must power on the generator before powering on the product Verify that the product is turned off before powering on the generator Terminals mar...

Page 5: ...em Strictly follow the installation and operating instructions Read the maintenance section of this document before servicing the product Shipping Use the original packaging for shipping the product u...

Page 6: ...rton and packing materials to be inspected by the carrier Carefully read this document in order to become familiar with the product and to identify the external documents containing essential informat...

Page 7: ...ation at 1 kHz 3 x 120 W 4 85 dB damping factor 400 1 kHz and below 8 output delay 0 ms to 1000 ms mains input power and current draw all channels driven maximum output power 4 x 1400 W RMS at 8 4 x 2...

Page 8: ...terface 2 x 24 characters LCD screen output connectors 2 x 4 point speakON 1 x 8 point CA COM L NET connectors 2 x 1 Gb s Ethernet etherCON Input Signal distribution connectors input 4 Neutrik female...

Page 9: ...l clock at 96 kHz Sample Rate Converter SRC sampling frequency 96 kHz SRC referenced to the amplified controller internal clock word length 24 bits dynamic range 140 dB distortion THD N 120 dBfs bandp...

Page 10: ...Network Manager 2 third party management solutions SNMP Extron Crestron Extron is a registered trademark of Extron Electronics Crestron is a trademark or registered trademark of Crestron Electronics...

Page 11: ...le dispositif de s curit de la prise de type terre Une prise de type terre est constitu e de deux contacts m les et d un contact femelle pour la connexion la terre Le contact femelle assure la s curi...

Page 12: ...er de reproduire un circuit 200 V en connectant l appareil deux phases d un circuit triphas 100 V Interconnectez syst matiquement un disjoncteur de classe C entre l appareil et le secteur L amp rage d...

Page 13: ...t 50 C 122 F N exposez pas l appareil au soleil Utilisez l appareil uniquement dans un environnement lectromagn tique conforme Les environnements conformes sont sp cifi s dans le standard EN55103 2 po...

Page 14: ...nsable assurant l installation ou l exploitation du produit en toute s curit Ce symbole signale un risque d accident lectrique Il peut galement signaler une instruction indispensable assurant l instal...

Page 15: ...soci t de transport ou le distributeur Seul le destinataire peut faire r clamation pour tout dommage occasionn pendant le transport Conservez le carton et les pi ces d emballage pour constatation de...

Page 16: ...s paration de canaux 1 kHz 3 x 120 W 4 85 dB facteur d amortissement 400 1 kHz et en dessous 8 d lai de sortie 0 ms 1000 ms Consommation de puissance et de courant tous canaux aliment s puissance de s...

Page 17: ...r le courant le statut et L NET pour chaque sortie 7 x LEDs pour informer sur le mute la charge le signal les niveaux et le limiteur cr tage interface cran LCD 2 x 24 caract res connecteurs de sortie...

Page 18: ...bits synchronisation signal re r f renc l horloge interne 96 kHz convertisseur de fr quence d chantillonnage SRC fr quence d chantillonnage 96 kHz SRC r f renc l horloge interne du contr leur r soluti...

Page 19: ...e gestion tierces SNMP Extron Crestron Extron est une marque d pos e de Extron Electronics Crestron est une marque ou marque d pos e de Crestron Electronics Inc aux tats Unis et ou dans d autres pays...

Page 20: ...Notes LA12X product information version 1 0 20 Notes...

Page 21: ...Notes 21 LA12X product information version 1 0...

Page 22: ...Notes LA12X product information version 1 0 22...

Page 23: ......

Page 24: ......

Reviews: