Specifications
9
LA12X product information version 1.0
Analog Input
input impedance
22 kΩ (balanced)
max. input level
22 dBu (balanced, THD 1%)
A/D conversion
4 cascaded 24-bit analog/digital converters (130 dB
dynamic range)
Digital Input
supported operating mode
standard
AES/EBU (AES3)
sampling frequency (Fs)
44.1, 48, 88.2, 96, 176.4 or 192 kHz
word length
16, 18, 20 or 24 bits
synchronization
signal resampled to internal clock at 96 kHz
Sample Rate Converter (SRC)
sampling frequency
96 kHz (SRC referenced to the amplified controller internal
clock)
word length
24 bits
dynamic range
140 dB
distortion (THD+N)
< -120 dBfs
bandpass ripple
± 0.05 dB (20 Hz - 40 kHz, 96 kHz)
automatic fallback option
mode
AB to CD
digital to analog
digital to digital
switchover conditions
no clock, loss of lock, CRC error, bipolar encoding error or
data slip
constant delay
independent of input Fs
constant level
upon user setting of AES/EBU gain, independent of input
Fs
revert to AES/EBU
upon manual user selection
input gain
range
-12 dB to +12 dB
steps
0.1 dB