LA4X
Amplified Controller
user manual
VERSION 4.0
LA4X_UM_EN_4.0
w w w . l - a c o u s t i c s . c o m
20
The table below describes the maximum number of enclosures a single LA4X amplified controller can drive.
Table 4: Maximum number of enclosures per LA4X
Technology
Loudspeaker
enclosure
Max number of connections
per output *
Max number of enclosures
per controller
Coaxial
5XT
4
16
8XT
2
8
Passive 12XT
1
4
Active 12XT
2
4
115XT HiQ
1
2
Constant
Curvature WST
ARCS
®
WIDE/FOCUS
1
4
ARCS
®
II
1
2
Variable Curvature
WST
KIVA KILO
2
8
KARA
®
2
4
KUDO
®
1
1
K2
1
1
Subwoofers
SB15m
1
4
SB18
1
4
* For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output.
For active loudspeakers, the value corresponds to the number of sections in parallel on the output.
3.4.5
L-NET cabling
The LA4X can be remote controlled over an Ethernet network (called L-NET) using LA NETWORK MANAGER
software (refer to the
LA NETWORK MANAGER video tutorial
).
To connect the LA4X to L-NET use the EtherCON connectors on the L-NET panel (see Figure 7). Each of the two
EtherCON connectors can be equally used as an IN or LINK connector.
Refer to the
LA NETWORK MANAGER video tutorial
for network setup (type of cables, physical connections,
network topology, etc.).