Loudspeaker congurations
X15 HiQ stage monitor with LF
Deployed as a stage monitor with SB18 subwoofers, an X15 HiQ system operates with augmented LF resources.
The [X15_MO] preset allows for a reference frequency response in stage monitoring applications.
The [SB18_100] preset provides the SB18 with an upper frequency limit at 100 Hz for an optimal frequency coupling
with the X15 HiQ.
The X15 HiQ and SB18 enclosures are driven by the LA4X / LA8 / LA12X amplied controllers.
X15 HiQ with SB18
With SB18, the X15 HiQ system contour is reinforced by 5 dB at 100 Hz, and the system bandwidth is extended down
to 32 Hz.
55°
35°
Enclosure X15 HiQ
SB18
Preset [X15_MO]
[SB18_100]
Frequency range (-10 dB) 32 Hz - 20 kHz
Enclosure ratio 1 X15 HiQ : 1 SB18
Delay values
Do not forget to add the pre-alignment and geometric delays depending on the conguration.
Pre-alignment delays
[X15_MO] + [SB18_100]
X15 HiQ = 0 ms
SB18 = 0 ms
[xx_MO] presets for the X series use the amplied controller low latency operating mode. When used along with
subwoofers, it is recommended to use the subwoofers in low latency operating mode. To achieve this, create
custom presets combining low latency channel sets and subwoofer channel sets.
If the subwoofers are driven from a dedicated amplied controller using a subwoofer factory preset, they are
operated in normal latency mode. Therefore, an additional delay should be set to the [xx_MO] low latency
channels to align them: 2.66 ms on LA8 or 3.00 ms on LA4X and LA12X.
X15 HiQ user manual (EN) version 5.0
13
Summary of Contents for X15 HIQ
Page 1: ...X15 HIQ user manual EN...