Rigging procedures
Mounting X4r in a ceiling tile with X4r inTile
type of deployment
ceiling-mounting
rigging accessories
X4r inTile, including:
• X4r enclosure
• X-U4i rigging accessory
• X4r-Tilescreen
1 max. Ø10 mm / 0.4 in threaded rod
3 corresponding nuts
2 corresponding washers
2 M5×16 Torx screws (provided)
additional material
tethers for secondary safety
torque screwdriver
tools
T25 Torx bit
min. number of operators
1
X4r-Tilescreen is only compatible with 600x600 mm (2x2 ft) tiles (European standard).
Secondary safety with X4r-Tilescreen
Use the available holes to implement a secondary safety.
200 mm / 7.9 in of room are required between the main ceiling and the suspended ceiling or wall to install the
enclosure assembly.
m
in
. 2
00
m
m
/ 7
.9
in
30
X4r owner's manual (EN) version 1.0
Summary of Contents for X4r
Page 1: ...X4r owner s manual EN...