Basic Unit Description and Application
Pilot ignition agricultural building heaters are direct-fired,
non-vented heaters used in the heating of animal
confinement buildings (examples: swine, chicken, and
turkey). These heaters utilize a system that ignites the gas
by a conventional pilot flame rather than by direct spark or a
hot surface igniter. L.B. White offers you the most
dependable pilot system in the industry. Tested and proven
over time, these heaters provide simple yet reliable
operation.
As a non-vented heater, adequate ventilation must be
provided to ensure fresh air for combustion and removal of
combustion by-products from the building.
This style of heater is offered in a wide range of input ratings,
some with variable heat control, to help manage heating
needs efficiently.
All heaters referred to in this guide are to be mounted inside
the building at appropriate locations to help provide proper
warm air flow in the room being heated.
Key Markings; Purpose and Location
Markings constitute safety related information such as the
dataplate, start-up/shut-down instructions, warnings, etc.
that are applied on the heater to allow the qualified service
person or end user to operate the heater in a safe manner.
A. Dataplate
Purpose:
Used for identification of model number, and
configuration number and also critical information
such as safe clearances to combustibles, burner
manifold pressure, maximum and minimum
allowable inlet pressures, etc.
Typical Location:
Interior or exterior of burner end access panel.
Part No.:
Varies with design sequence and model number.
Contact L.B. White Co.
B. Start Up and Shut Down Procedures
Purpose:
Provides the basic information to safely start up and
shut down the heater and also provides cautionary
information relative to various safety aspects of
installation and application.
Typical Location:
Next to dataplate.
Part No.:
150-20158
Familiarize yourself with the location and content of all
markings. Location may vary depending on model. If any
markings are damaged or unreadable, replace the markings
immediately. Contact the L.B. White Company.
General
Information
August 1999
MODEL AW060
CONFIGURATION NO. AHPD210000
SERIAL NO.:
L. B. WHITE CO., INC. W6636 L.B. WHITE ROAD ONALASKA, WI 54650 608/783-5691
A
G S
DESI GN
CERTIFI ED
A
A
A
MERI C N
SSOCIATI O
N
MAXIMUM INPUT: 60,000 BTUH
TYPE FUEL: PROPANE VAPOR WITHDRAWAL
BURNER MANIFOLD PRESSURE 10.0 IN W.C. AT MAXIMUM INPUT
ELECTRICAL: 115 VOLTS A.C. 60 HZ SINGLE PHASE 1.5 AMPS
MIN. CLEARANCES FROM HEATER TO ADJACENT COMBUSTIBLE MATERIALS: REAR 1 FT SIDES 1 FT
TOP TO CEILING 1 FT BLOWER OUTLET 6 FT AND FUEL CONTAINER 6 FT
VENTILATION: 240 CFM OF AIR REQUIRED TO SUPPORT COMBUSTION.
MAXIMUM 13.5 INCHES W.C. AND MINIMUM 11.5 INCHES W.C. GAS SUPPLY PRESSURE
ACCEPTABLE AT INLET 0F HEATER FOR PURPOSE OF INPUT ADJUSTMENT.
POSITION HEATER AWAY FROM LIVESTOCK
AGRICULTURAL BUILDING HEATER
1.1-1
1
AB250
250,000