background image

IP-00108 Rev. A – 06/10 Page 2/3

L-com, Inc. – 50 High St., West Mill, Suite #30 – North Andover, MA 01845 USA 

1-800-343-1455  •  www.L-com.com            

Copyright © This drawing is property of L-com, Inc. All rights reserved. 

BT-CAT5-NB12 User Manual

Cable Specification:

The BT-CAT5-NB12 and NB141207-4H0 can use CAT5 cabling wired to meet either EIA 568-A or EIA 568-B
specifications. Failure to use the proper cable, or one incorrectly fabricated could result in a short of the
48VDC power that is fed through the cable from the BT-CAT5-NB12 to the NB141207-4H0. Use of improper
cables is not covered by the products warranty.

 

2

#

 

r

o

t

c

e

n

n

o

C

 

1

#

 

r

o

t

c

e

n

n

o

C

              1 WHT/ORG 

              2 ORG 

              3 WHT/GRN 

              4 BLU 

              5 WHT/BLU 

              6 GRN 

              7 WHT/BRN 

              8 BRN 

               1 WHT/ORG 

               2 ORG 

               3 WHT/GRN 

               4 BLU 

               5 WHT/BLU 

               6 GRN 

               7 WHT/BRN 

               8 BRN

 

 

2

#

 

r

o

t

c

e

n

n

o

C

 

1

#

 

r

o

t

c

e

n

n

o

C

              1 WHT/GRN 

              2 GRN 

              3 WHT/ORG 

              4 BLU 

              5 WHT/BLU 

              6 ORG 

              7 WHT/BRN 

              8 BRN 

                1 WHT/GRN 

                2 GRN  

                3 WHT/ORG 

                4 BLU 

                5 WHT/BLU 

                6 ORG 

                7 WHT/BRN 

                8 BRN

 

CAT5 (EIA 568-B) Cable

CAT5 (EIA 568-A) Cable

48VDC

POWER

SUPPLY

48VDC

POWER

SUPPLY

PORT 1

PORT 12

3A

3A

1
2
3
4
5
6

7

8

1
2
3
4
5
6

7

8

L

G

N

L

G

N

120 VAC

INPUT

BT-CAT5-NB12 DIAGRAM

Reviews: