135lb Stainless Steel Spreader Installation
6.0
TROUBLESHOOTING
Controller Error
Light pattern - Flashing
1 2 3 4 5 6 7 8 9
10
Over Current
X X
Short Circuit
X X X
Open Circuit
X X X X
Low Voltage - 9.5 V
X X X X X
High Voltage - 14.8 V - 19V
X X X X X X
Over Temperature - 60°C (140°F) X X X X X X X
Problem
Possible Cause
Corrective Action
Controller will not turn on
1. Controller is not connected to
Power/Ground harness.
2. Bad Connection at
Power/Ground harness.
3. Dead/Low Battery
4. Blown fuse in Controller
Harness
5. Blown fuse in Power/Ground
Harness.
1. Connect Controller to
Power/Ground harness.
2. Disconnect controller from
the Power/Ground harness.
Clean terminals and re-connect
controller.
3. Turn off all electrical
equipment (Lights, Pump,
Spreader, etc.). Start engine
manually. Let the engine charge
the battery then continue
operation.
4. Check fuse in the controller
harness between controller and
connection to power/ground
harness. Replace if blown.
5. Check for power and ground
at connector. If there is no
power check for power on the
other connectors. If there is no
power on the other connectors.
Examine electrical and find
where the short is, replace
damaged component(s).
Replace Power/Ground harness.