23. Input
control.
This controls the input gain from –12dB to +12dB. In this mono mode, this
is the units only input gain control.
24. Low/Mid xover freq.
This control governs the crossover frequency between low and
middle bands.
25. Mid/High xover freq.
This control governs the crossover frequency between middle and
high bands.
26. Mid
output.
This controls the output level of the mid
band from 0dB to +6dB.
27. Mid phase invert.
This switch reverses the polarity of the mid output.
When pressed the
LED will light.
28. High output control.
This controls the output level of the high band over the range from
0dB to +6dB.
29. Input
connector.
Balanced XLR input. This is the units only input when in this mode.
30. Xover freq switch.
This is used to switch between the control range of LOW/MID XOVER
FREQ on the front panel The range is either 45Hz-960Hz or 450Hz to 9.6KHz.
31. Xover freq switch.
This is used to switch between the control range of MID/HIGH XOVER
FREQ on the front panel The range is either 45Hz-960Hz or 450Hz to 9.6KHz..
32. Low
output
connector.
Balanced XLR for the low output signal.
33. Mid
output
connector.
Balanced XLR for the mid range output signal.
34. High output connector.
Balanced XLR for the high output signal.
35. Mode switch.
This switch must be IN when in mono mode. PLEASE NOTE. NEVER ACTIVATE
THE MODE AND CROSSOVER SWITCHES WITH THE UNIT SWITCHED ON.