14.3.2.14 Power Input Interface
The Modem operates with input voltage ranges of 90-132 VAC (110 VAC nominal) and
180-264 VAC (220 VAC nominal) and input frequency from 47 Hz to 63 Hz. The Modem
supports AC input auto ranging. This interface is located on the rear panel J11
connector.
Table 14-13 Power Input Interface
CONN
Signal Name
Input/Output
Signal Description
Pin
J11
NO
CONNECT
N/A
No Connection
D
J11
LINE
Input
AC Input
C
J11
NEUTRAL
Output
AC Return
B
J11
GROUND
N/A
Safety Ground
A
14.3.2.15 Antenna Power Interface
The Modem provides an Antenna Power Input Interface. The DC power presented at
this interface is multiplexed onto the primary TX IF Interface. The DC voltage presented
at this interface must be between 17.5 and 48.5 volts, and capable of sourcing 3 A
maximum. This interface is located on the rear panel J14 connector.
Table 14-14 Antenna Power Interface
CONN
Signal Name
Input/Output
Signal Description
Pin
J14
ANTENNA DC
IN
Input
17.5 TO 48.5 volts; 3 Amax
1, 2, 3
J14
ANTENNA DC
RETURN
Output
Ground return
4, 5, 6
14.3.2.16 RS-485 SCPC Control Interface
The Modem provides a RS-485 interface for modem control and monitoring. The
Modem Control/Status Port is a bi-directional, asynchronous interface that may be used
to control the Multi-Purpose Modem directly in the MIL-STD-188-165A Single Channel
Per Carrier (SCPC) mode. This interface does not provide the overall control of the IP-
Modem. The Serial Control/Status interface complies with RS-485 and supports a
maximum data rate of 115.2 kbps. The data rate and device address of the Serial
Control/Status Port is settable. The format and protocols of the Serial Control/Status
Port commands and responses are specified in L-3 Communications Linkabit ICD
118949. This interface is located on the rear panel J4 connector.