COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
FA2100CVR
Rev. 15 Page 116
Apr. 14/16
Testing & Fault Isolation
23–70–04
Use or disclosure of information on this sheet is subject
to the restrictions on the cover page of this document.
(j)
From the pull down menu , click on Test=> Test Mode=> Return
−
to
−
Ser-
vice Test. Ensure that the Return
−
to
−
Service is checked.
(k)
From the pull down menu, click on Test=>Start Test.
(l)
Follow the instructions below as it appears presented by the software.
(m) Read and click on Yes.
Figure 114. CVR Test, Instruction Message
(n)
Read and click on OK.
Figure 115. CVR Test, Warning Message
(o)
Remove front cable and click on OK.
Figure 116. CVR Test, Instruction Message
(p)
Enter in the current value in amps (typically .085) in window and click on
OK.
The document reference is online, please check the correspondence between the online documentation and the printed version.