COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
Model FA5000
Rev. 03 Page 212
Feb. 27/13
FDR Function Testing & Fault Isolation
23–70
−
40
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
Scroll
Arrow
Figure 203. Recorder Automatic Test Information Pop
−
Up Screen
NOTE:
The User can select one of two test duration options; however
for this test procedure, use only the Single Pass Test Option.
Single Pass Test
−
monitor data and dump data will be quickly
verified in one test pass.
Single Pass Test for XX hours and XX minutes
−
monitor
data will be quickly verified, then data will be recorded for the
specified number of hours and minutes and then dumped and
verified.
Full Memory Test
−
monitor data will be quickly verified, then
data will be recorded to fill memory and then dumped and veri-
fied. This test will take from 12 to 16 hours to complete.
(7)
Observe in the window the following status messages as the test progresses:
Starting automatic test monitor data verification pass 1.
Successful completion of monitor data verification.
Starting data dump comparison testing.