INSTALLATION
Initial advices
•
The stove must be installed on a floor with adequate capacity. If the existing building does not
meet this requirement, appropriate measures (eg, load distribution plate) must be taken.
•
The installation must guarantee easy access to clean the stove, the smoke pipes and the chimney
flue as well.
•
Air extraction fans, when installed in the same space or room with the stove can cause draft
problems
•
All local regulations must be respected in the installation of the stove.
•
Do not use the stove as an incinerator or in any other way different from the one it has been
conceived for.
•
Do not use fuels different from those recommended.
•
Do not use liquid fuels.
•
The stove, especially the external surfaces, while it is working gets hot to the touch. Handle
carefully to avoid burns.
•
Do not perform any unauthorized modification to the stove.
•
Use only original replacement parts recommended by the Manufacturer.
INSTALLATION DISTANCES FROM FLAMMABLE MATERIAL
Minimum installation distances from flammable material
- Minimum distance from lateral flammable wall/material: 200 mm
- Minimum distance from rear flammable wall/material: 200 mm
- Minimum distance from flammable floor: 80 mm
Minimum distance from front flammable material: 1000 mm