English
English
8.7 CPU Menu - Parameters Programming
Parameters
Low pressure NO
Milk temp. block
NO
No Milk block
NO
!
Press the “+” and “-” keys (
30
) to activate (
YES
) or not activate (
NO
)
the “
no milk block
” function.
When this function is activated dispensing of all milk-based drinks will
be blocked if the milk containers are empty.
8.7.6)
Press the "
"""
" key (
31
) to
move to the line below. The
following message will be
displayed:
!
Press the “+” and “-” keys (
30
) to activate (
YES
) or not activate (
NO
)
the "
milk temperature block
” function.
When this function is activated, if the refrigerator unit temperature is
not correct dispensing of all milk-based drinks will be blocked (INACTIVE
FUNCTION).
1. Display Panel - Description (4)
COMPONENTS
24
“RES” key (reset)
25
“EXIT” key (quit programming)
26
Coffee circuit wash key
27
Counters display key
28
Milk circuit wash key
29
“PRG” key (access programming function)
30
“+” and “-” keys (change parameters/clock)
31
"
"""
" key (change language and move cursor)
SPECIAL FUNCTION KEYS
53
Milk selection with second container key (and led)
54
STOP dispensing keys
55
Coffee selection with second blend key (or led)
24
54
55
53
29
31
30
30
27
25
28
26
!
Parameters
Cleaning start MAN
Low power NO
Low pressure NO
8.7.5)
Press the “
"""
” key (
31
). The
arrow moves to the next line down
and the following message will be
displayed:
Press the “+” or “-“ keys (
30
) to activate (
YES
) or deactivate (
NO
) the
“pressure block” function.
If the function is activated (
YES
) when the general boiler pressure value
is 0.3 bar less than the programmed pressure, the dispensing of hot
water, milk and cappuccino will be suspended until the correct pressure
value has been set.
8.7.8)
Press the “
"""
” key (
31
). The
arrow moves to the next line down
and the following message will be
displayed:
Parameters
Milk temp. block NO
No Milk block
NO
Standard data NO
!
Press the “+” or “-“ keys (
30
) to load (
1
or
2
) or not load (
NO
) the
standard data.
Position the indicator on “
1
” and press the PROG key (
29
) to load the
standard data for the “Cappuccino” version machines (
C
).
Position the indicator on “
2
” and press the PROG key (
29
) to load the
standard data for machines “without Cappuccino” (
S
).
8.7.7)
Press the "
"""
" key (
31
) to
move to the line below. The
following message will be
displayed:
Parameters
Low power NO
Low pressure NO
Milk temp. block NO