9. Technical Data
This cooker is category:
Cat II 2H3B/P; Cat II 2H3+; Cat II 2E+3+; Cat II 2E3B/P; Cat II 2L3B/P; Cat II 2ELL3B/P
It is supplied set for group H natural gas.
A conversion kit to other gases is supplied .
INSTALLER:
Please leave these instructions in the folder in the instruction pack
and hand them to the user.
DATA BADGE LOCATION:
Inside base drawer of cavity – remove the drawer.
For removal of drawer see installation instructions.
COUNTRY OF DESTINATION:
UK/FR/DE/NL/DK/NO/SWE/GR/PL/RU/ES/IT/PT/AT/BE/CH/IE/LU
Gas
Electric
Natural Gas
20mbar
230/400V 50Hz
Min 16A/phase
Propane
37mbar
Butane
29mbar
(See appliance data badge for test pressures).
Dimensions
Oven Efficiency
Overall height
minimum 910mm
maximum 937mm
Overall width
900mm See ‘Positioning of Cooker’.
Overall depth
720mm
Space for fixing
see “Positioning of Cooker’.
Minimum space for
cooktop
800mm
Connections
Gas
Electric
Rp ½” at rear right-hand side
Rear right-hand side
Ratings
Oven
Full
Divided
Fan Element
3.31kW
1.65kW
Top Element
3.49kW
1.75kW
Browning Element
2.11kW
1.06kW
Bottom Element
1.38kW
0.69kW
Maximum total electric load 230V 3.6kW (approximate total inc. oven fans, etc.)
Hotplate
Natural Gas
LP Gas
Centre Burners
4kW
4kW (285 g/h)
Large Burners
3kW
3kW (214g/h)
Right Front Burner
1.7kW
1.7kW (121g/h)
For further information, please see conversion instructions.
Oven
Energy Efficiency Class
A
Energy consumption based on
standard load
0.90kWh
Useable volume (litres)
108
Size
Large
Time to cook standard load
44 mins
Baking area
2400cm²
ArtNo280-0090 Drawer Cavity & Badges