ELECTRICAL DIAGRAM

 

Hood with internal Motor 

Summary of Contents for Chateau series

Page 1: ......

Page 2: ...Technical characteristics of hood equipment 7 3 LaCornue hood Dimensions and technical information 8 10 ASSEMBLY INSTRUCTIONS 11 16 ELECTRICAL DIAGRAM 17 18 WARRANTY 19 20 All of the characteristics a...

Page 3: ...ment manu facturer s guideline and safety standards such as those pub lished by the National Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When...

Page 4: ...etwork only a qualified electrician may connect the hood to the elec tric current In this case the electrician must connect the hood to a single phase alternating current circuit equipped with a bipol...

Page 5: ...alling the hood as close as possible to the ventilation shaft Your hood is an external ventilation model Do not evacuate the air to areas with walls and ceilings e g Roof space attics garages Check th...

Page 6: ...ornue Ch teau line hood models With our special individual manu facturing principle offering a wide variety of models it is quite possible that you may not find the description or the technical charac...

Page 7: ...0 V a c single phase earth 60 Hz for 1 motor version and 4 LED Lights Nominal flow 600 cfm Electrical power 460W Current 3 8 A Lighting light LED power 2 5 W Filter Stainless steel Dimensions 300 x 40...

Page 8: ...0 4E RC Grand Palais 180 Ch teau 165 Ch teau 150 Grand Ch telet 135 Ch teau 120 Ch teau 90 Ch teau 75 X 1 mm 2000 1850 1700 1550 1400 1100 950 X 2 mm 1600 1450 1300 1150 1000 700 550 X 3 mm 1744 1594...

Page 9: ...INFORMATION Grand Palais 180 Ch teau 165 Ch teau 150 Grand Ch telet 135 Ch teau 120 Ch teau 90 Ch teau 75 L 2000 1850 1700 1550 1400 1100 950 L 2 1000 925 850 775 700 550 475 B 1590 1440 1290 1140 990...

Page 10: ...lais 180 Ch teau 165 Ch teau 150 Grand Ch telet 135 Ch teau 120 Ch teau 90 Ch teau 75 Y 2000 1850 1700 1550 1400 1100 950 Y 1 1800 1650 1500 1350 1200 900 750 Y 2 1515 1365 1215 1065 915 615 465 Y3 17...

Page 11: ...he external extraction ventilation shaft in the wall or in the ceiling To guarantee the best smoke extraction results the hood must be centred in relation to the cooking To facilitate mounting start b...

Page 12: ...ng Drill the holes indicated on the jig in the wall and insert pegs adapted to the type of wall Fix the assembly jip into holes C with long screws and into the upper and lower holes d D with the threa...

Page 13: ...ge Please note The ventilation shaft must not be folded or crushed Perform the electrical connections 7 1 ELECTRICAL CONNECTIONS HARD WIRE FROM HOME POWER SUPPLY Electrical Shock Hazard Disconnect pow...

Page 14: ...des of the body 9 Fit the mantel B onto the threaded rods K using the provide nuts The hood mantel must not be twisted Using a 90 degree screwdriver screw the mantel at the Bottom via the hatch and at...

Page 15: ...place by sliding it in parallel above The Hood mantel The two clips on the rear lugs L must be inserted into the holes H on the ferrule The screws G on the left and right of the hood must simultaneous...

Page 16: ...fix them in place on the left and right with a M3 screw Fix the connecting pierce in place J ASSEMBLY INSTRUCTIONS 11 Fix the 5 star plate to the listel connecting piece J with 3 M3 screws 12 Positio...

Page 17: ...en 17 ELECTRICAL DIAGRAM Hood with internal Motor...