Technical Data
This range is supplied set for Natural gas.
A conversion kit from Natural Gas to Propane gas is included.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Inside base of drawer cavity - remove drawer. For removal of drawer see installation
instructions.
Country of Destination: USA/Canada
Gas
Electric
Natural Gas
4.0” W.C (10 mbar)
240V 60Hz
Propane 10.0”
W.C
(25
mbar)
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 35 13/16” (91 cm)
maximum 36 7/8” (93.7 cm)
Overall width
43” (109.2cm) See ‘Positioning the Range’
Overall depth
28 5/8” (72 .5cm).
Space for fi xing
See ‘Positioning the Range’
Minimum space above cooktop
31.5” (80cm)
Connections
Gas :
Electric:
½” NPT at rear right-hand side
240 V 60 Hz
Ratings
Cooktop
Natural Gas
Propane Gas
Input
Orifice
Screw
Input
Orifice
Screw
Center burner
17,500 Btu/hr
205
82
17,500 Btu/hr
118
49
Large Burners
12,000 Btu/hr
150
70
12,000 Btu/hr
99
38
Right hand front Burner
6,000 Btu/hr
112
53
6,000 Btu/hr
68
31
Gas burner inputs based on Gross Calorifi c Value