Adjustments
Open top, hot top, open top broiler or gridd le
Only the low settings for the burners of the open tops, hot top, open top broiler or griddle can be adjusted
by means of the following procedure:
1.
Turn gasburner on and set to lowest setting (small flame).
2.
Remove the control knobs (A) and knob bezel by
unscrewing the allen screw to access the by-pass screw.
3.
Rotate the by-pass screw on the valve body
to the left to
increase
the flow rate,
to the right to reduce it
.
Only for natural gas reduced flow rate can be adjusted.
For the propane gas tighten the screw down.
Make sure that the resulting flame, at the lowest setting, is
sufficiently strong to heat the thermocouple.
4.
Place back control knob bezel and control knob and proceed with testing.
Caution: Make sure that there is a sufficient gap between the knobs and the
front panel, since it is necessary to ful ly depress the knob before rotating it
when igniting the burners.
Caution: Before proceeding with the conversion, shut off the gas supply to the appliance prior to
disconnecting the electrical power.
The orifices size depends on the type of gas. The table below is provided for you to determine which orifice
should be used if the type of gas is changed.
1. A
DJUSTMENTS OF THE TOP BURNER LOW FLAME SETTINGS
2. F
UEL CONVERSION
by-pass screw
A