background image

Model: 308A-146                       www.lacrossetechnology.com/support                                  Page | 7  
 

8. 

Press and release the 

+

 or 

-/°C/°F

 button to set the date. 

9. 

Confirm all calendar settings with the SET button to confirm and exit the program 
menu. 

 

Note:

 The day of the week will set automatically once the year, month and date are set. 

 

Fahrenheit/Celsius 

 

1.

 

Press and release the 

-/°C/°F 

button once to switch 

from Fahrenheit to Celsius.  

 
                              

Time Alarm Set 

 

Hold the 

ALARM

 button for 5 seconds to enter the alarm time set 

mode.

 

 

1.

 

The alarm hour digit will flash. 

2.

 

Press and release the 

+

 or 

-/°C/°F

 button to select the hour.  

3.

 

Press and release the 

SET

 button to set the minutes. The minute 

digits will flash. 

4.

 

Press and release the 

+

 or 

-/°C/°F

 button to select the minutes. 

5.

 

Confirm with the SET button and exit. 

6.

 

The alarm icon will show above the minutes indicating the alarm is 

active. 

7.

 

The alarm icon will flash when the alarm is sounding.      

 

Deactivate Alarm 

 

1.

 

Press and release the 

ALARM

 button once to show alarm time.  

2.

 

Press and release the 

ALARM

 button to deactivate the Alarm.  

3.

 

The bell icon will disappear indicating the alarm is no longer active.  

 

Snooze 

 

1.

 

When the alarm sounds, press the SNOOZE/LIGHT button to trigger snooze alarm for 
10 minutes.  The snooze icon Zz will flash when the snooze feature is active. 

2.

 

To stop alarm for one day, press ALARM button, while in snooze mode. The alarm icon 
will remain solid. 

Note

: When the alarm sounds, it continues for 2 minutes, then shuts off completely.   

 

Adjust Backlight (HI-LOW-OFF) 

 

The backlight can show continuously when operating the forecast station with 
the 5-volt a/c adapter.  

 

1.

 

HIGH: The backlight is defaulted to HI (brightness) when the a/c adapter is in use. 

2.

 

LO: Press and release the 

LIGHT HI/LO

 button to dim the brightness of the 

backlight.   

3.

 

Press and release the 

LIGHT HI/LO

 button again to return to full strength (HIGH). 

 

Note:

 When the Adapter is NOT in use, the High/Low backlight feature is not available. 

 

1.

 

OFF: Hold the 

HOLD ON/OFF

 button for 5 seconds, until the station beeps, to turn 

the backlight off to sleep.  

2.

 

ON: Hold the 

HOLD ON/OFF

 button again until the station beeps, to turn the 

backlight on. 

Summary of Contents for 308A-146

Page 1: ...door readings Temperature Humidity Heat Index Dew Point MIN MAX Snooze Light button Forecast icons Sunny Partly Sunny Cloudy Rainy Stormy All icons are shown in this illustration Indoor readings Tempe...

Page 2: ...plug the AC adapter and remove batteries from the forecast station sensor and press any button 20 times After 15 minutes return to Step 1 above Table of Contents WIRELESS COLOR FORECAST STATION 1 Quic...

Page 3: ...ging barometric pressure Measure in out temperature and humidity with daily min max records all on one easy to read color display with adjustable brightness Features 12 24 hour time with snooze alarm...

Page 4: ...ht will illuminate for 8 seconds when using only battery power with a press release of the SNOOZE LIGHT button STEP 3 Ensure that the sensor is within 10 feet of the forecast station Remove battery co...

Page 5: ...Time Display Press to switch from Fahrenheit to Celsius temperature readings MIN MAX Button Default Time Display Press once to view MAX values then MIN values Hold for 2 seconds to reset all MIN MAX v...

Page 6: ...me Note When in 12 hour format AM or PM will show in front of the hour 1 12H will flash 2 Press and release the or C F button to select 24 hour time 3 Confirm with the SET button and move to Set Time...

Page 7: ...m time 2 Press and release the ALARM button to deactivate the Alarm 3 The bell icon will disappear indicating the alarm is no longer active Snooze 1 When the alarm sounds press the SNOOZE LIGHT button...

Page 8: ...moisture content of the air at a given temperature Dew Point Temperature is the absolute measure of the moisture in the air at a given temperature Relative humidity is the relative measure of moistur...

Page 9: ...ugh the channels for all connected sensors Press and release the CH button to lock the forecast station into one channel Then view channels individually with a press of the CH button MIN MAX View Rese...

Page 10: ...s preferred The maximum wireless transmission range to the forecast station is over 300 feet 91 meters in open air not including walls or floors Be sure the outdoor sensor is mounted vertically Care a...

Page 11: ...or primary power TX142THv2 Outdoor Sensor Battery life is over 24 months when using reputable battery brands for both Alkaline and Lithium batteries Dimensions Forecast Station 6 3 L x 2 75 W x 4 25 H...

Page 12: ...equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device must not be co located or ope...

Reviews: