Wind Speed Weather Station

Change Batteries

TX141Wv2 Sensor:

1. Grab the vented portion of the sensor and turn counter clockwise.

2. Remove old batteries and install fresh “C” batteries.

3. Carefully align and turn vented portion clockwise to tighten.

4. Hold the WIND button on the weather station for 3 seconds to search for the sensor.

TX141Wv2 Sensor

Optional Add-on

TX141TH-BCH  Sensor

Add-on TX141TH-BCH Sensor(s):

1. Slide battery cover down and lift off sensor.

2. Remove old batteries and install fresh “AA” batteries.

3. Hold the TEMP button on the weather station for 3 seconds to search for the sensor.

• Hold the WIND button for 3 seconds to search for the wind sensor.

• Hold the TEMP button for 3 seconds to search for add-on temp/humidity sensors.

• If the signal is lost, the unit will display the last data recorded for 30 minutes. If the 

   signal is still not received after this time, dashes will be displayed on screen. 

• After 60 minutes, the station will begin to search for the missing signal automatically.

• The signal strength indicators will flash while searching and be solid when connected.

Sensor Search

Channel

 Selector

TX button

(Transmission)

Red LED

Flashes during 

transmission

AA

1    2    3

AA

AA

AA

Mounting Hole

Wind cups

C

C

Red LED

Flashes during 

transmission

Battery cover

Mounting pole

Mounting 

Bracket

Summary of Contents for 327-1417BW

Page 1: ...Professional Wind Station Instructional Manual Model 327 1417BW DC 030417 For online video support http bit ly LaxTechTalk...

Page 2: ...rend Arrows Frost and Storm Warnings Activate Deactivate Frost or Storm Warnings 3 3 4 4 5 6 6 6 7 7 8 8 9 9 9 10 10 Weather Forecast Icons Forecast Trend Arrows Change Batteries Sensor Search Connect...

Page 3: ...nd screwdriver within reach of setup location Keep sensor and weather station within 5 10 feet for at least 15 minutes after installing batteries This allows the sensors and station to sync properly a...

Page 4: ...er 1 BEEP ON OFF 2 Hour 3 Minutes 4 12h 24h hour format 5 Year 6 Month 7 Date 8 Temperature C F 9 Wind speed select mph kmh Note Press only one button at a time while in the settings menu Buttons Butt...

Page 5: ...the week is set automatically after Year Month and date are specified To begin Hold the SET button 3 seconds then release 1 BEEP ON OFF 2 Hour 3 Minutes 5 Year 6 Month 7 Date 9 MPH KMH FEELS LIKE OUT...

Page 6: ...t record Month Defined by Calendar Month i e January 1 January 31 Year Defined by Calendar Year i e January 1 December 31 Note After 5 seconds all readings default back to the 1 hour top wind speed Wi...

Page 7: ...to view HI LO temperature and humidity readings with time date stamp Press and release TEMP again to view the next value Outdoor temperature HIGH Outdoor temperature LOW Outdoor humidity HIGH Outdoor...

Page 8: ...s to reset each individual value Individual readings will reset to current temperature humidity etc Set Weather Alerts Hold the ALERTS button for 3 seconds to enter alert set mode High Wind Speed ON O...

Page 9: ...oor LOW Humidity Value 10 RH to 99 RH Indoor HIGH Humidity ON OFF Indoor HIGH Humidity Value 10 RH to 99 RH Active Alert When armed alert value is reached station will beep 5 times each minute until o...

Page 10: ...eactivate frost and storm warnings 3 Press and release the WARNING button to confirm and move to the next item Note The warning values are not programmable You can only activate deactivate the frost o...

Page 11: ...on to stop the sound Storm warning icon will still flash The forecast icons are determined by the station s barometric pressure reading Allow 7 10 days for best accuracy When Outdoor temperature is be...

Page 12: ...weather station for 3 seconds to search for the sensor Hold the WIND button for 3 seconds to search for the wind sensor Hold the TEMP button for 3 seconds to search for add on temp humidity sensors If...

Page 13: ...ction is established the temperature and humidity for each of the selected channels will appear 7 Install the battery covers on each sensor 8 Keep sensors and the wind station 5 10 feet apart for 15 m...

Page 14: ...to secure 5 Use screws through the bottom of the mounting bracket to attach 6 The sensor can be mounted from the bottom or side Alternatively 1 Insert your own mounting pole into the sensor 2 Tighten...

Page 15: ...n the flat side of the metal stem on the wind sensor Flat Side Of Stem Up Insert and Attach Flat End up Replace Wind Cups Factory Reset Clear Memory 1 Hold down both the WARNING and ALERTS button toge...

Page 16: ...interest For personalized interaction Join the conversation Latest video content Pin and share Care and Maintenance Do not mix old and new batteries Do not mix Alkaline Standard Lithium or Rechargeabl...

Page 17: ...180 kMh Update Interval About every 30 seconds Transmission Range 330 feet 100 meters RF 433MHz Weather Station 3 AA IEC LR6 batteries not included TX141Wv2 Wind sensor 2 C IEC LR14 batteries not inc...

Page 18: ...e may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Caution The manufacturer is not responsible for a...

Reviews: