background image

Page | 9

327-1417BW

Wind Speed Weather Station

Programmable Alerts

Here is the setting order for the 9 programmable alerts.

• High Wind Speed ON/OFF (CURRENT wind) 

• High Wind Speed Value 0-99mph (0-159kph) 

• Outdoor LOW Temperature ON/OFF 

• Outdoor LOW Temperature Value -40°F to 140°F (-40°C to 60°C) 

• Outdoor HIGH Temperature ON/OFF 

• Outdoor HIGH Temperature Value -40°F to 140°F (-40°C to 60°C) 

• Outdoor LOW Humidity ON/OFF 

• Outdoor LOW Humidity Value 10%RH to 99%RH 

• Outdoor HIGH Humidity ON/OFF 

• Outdoor HIGH Humidity Value 10%RH to 99%RH 

• Indoor LOW Temperature ON/OFF 

• Indoor LOW Temperature Value 32°F to 99°F (0°C to 37°C) 

• Indoor HIGH Temperature ON/OFF 

• Indoor HIGH Temperature Value 32°F-99°F (0°C to 37°C) 

• Indoor LOW Humidity ON/OFF 

• Indoor LOW Humidity Value 10%RH to 99%RH 

• Indoor HIGH Humidity ON/OFF 

• Indoor HIGH Humidity Value 10%RH to 99%RH

Active Alert

• When armed alert value is reached, station will beep 5 times each minute, until 

   out of alert range.

 The flashing alert icon will indicate which alert is sounding.

• Press any button to stop the alert sound. 

 The alert icon will flash while value is in alert range.

Disarm Alert:

1. Hold the ALERTS button for 3 seconds to enter alert set mode. 

2. Press and release ALERTS button until you see the alert you wish to disarm.

3. Press the +/- buttons to disarm the alert.

4. Press the WARNING button to exit.

Temperature | Humidity Trend Arrows

• The temperature and humidity trend arrows update every 15 minutes. The trend 

   reflects changes (2°F and 3% humidity) over the past 1 hour. E.g.: At 1:00 - compare 

   to 12:00 data; at 1:15 compare to 12:15: at 1:30 - compare to 12:30 ….. etc

Up Arrow:

 

Rising

Down Arrow:

 

Falling

Right Arrow:

 

Steady

Summary of Contents for 327-1417BW

Page 1: ...Professional Wind Station Instructional Manual Model 327 1417BW DC 030417 For online video support http bit ly LaxTechTalk...

Page 2: ...rend Arrows Frost and Storm Warnings Activate Deactivate Frost or Storm Warnings 3 3 4 4 5 6 6 6 7 7 8 8 9 9 9 10 10 Weather Forecast Icons Forecast Trend Arrows Change Batteries Sensor Search Connect...

Page 3: ...nd screwdriver within reach of setup location Keep sensor and weather station within 5 10 feet for at least 15 minutes after installing batteries This allows the sensors and station to sync properly a...

Page 4: ...er 1 BEEP ON OFF 2 Hour 3 Minutes 4 12h 24h hour format 5 Year 6 Month 7 Date 8 Temperature C F 9 Wind speed select mph kmh Note Press only one button at a time while in the settings menu Buttons Butt...

Page 5: ...the week is set automatically after Year Month and date are specified To begin Hold the SET button 3 seconds then release 1 BEEP ON OFF 2 Hour 3 Minutes 5 Year 6 Month 7 Date 9 MPH KMH FEELS LIKE OUT...

Page 6: ...t record Month Defined by Calendar Month i e January 1 January 31 Year Defined by Calendar Year i e January 1 December 31 Note After 5 seconds all readings default back to the 1 hour top wind speed Wi...

Page 7: ...to view HI LO temperature and humidity readings with time date stamp Press and release TEMP again to view the next value Outdoor temperature HIGH Outdoor temperature LOW Outdoor humidity HIGH Outdoor...

Page 8: ...s to reset each individual value Individual readings will reset to current temperature humidity etc Set Weather Alerts Hold the ALERTS button for 3 seconds to enter alert set mode High Wind Speed ON O...

Page 9: ...oor LOW Humidity Value 10 RH to 99 RH Indoor HIGH Humidity ON OFF Indoor HIGH Humidity Value 10 RH to 99 RH Active Alert When armed alert value is reached station will beep 5 times each minute until o...

Page 10: ...eactivate frost and storm warnings 3 Press and release the WARNING button to confirm and move to the next item Note The warning values are not programmable You can only activate deactivate the frost o...

Page 11: ...on to stop the sound Storm warning icon will still flash The forecast icons are determined by the station s barometric pressure reading Allow 7 10 days for best accuracy When Outdoor temperature is be...

Page 12: ...weather station for 3 seconds to search for the sensor Hold the WIND button for 3 seconds to search for the wind sensor Hold the TEMP button for 3 seconds to search for add on temp humidity sensors If...

Page 13: ...ction is established the temperature and humidity for each of the selected channels will appear 7 Install the battery covers on each sensor 8 Keep sensors and the wind station 5 10 feet apart for 15 m...

Page 14: ...to secure 5 Use screws through the bottom of the mounting bracket to attach 6 The sensor can be mounted from the bottom or side Alternatively 1 Insert your own mounting pole into the sensor 2 Tighten...

Page 15: ...n the flat side of the metal stem on the wind sensor Flat Side Of Stem Up Insert and Attach Flat End up Replace Wind Cups Factory Reset Clear Memory 1 Hold down both the WARNING and ALERTS button toge...

Page 16: ...interest For personalized interaction Join the conversation Latest video content Pin and share Care and Maintenance Do not mix old and new batteries Do not mix Alkaline Standard Lithium or Rechargeabl...

Page 17: ...180 kMh Update Interval About every 30 seconds Transmission Range 330 feet 100 meters RF 433MHz Weather Station 3 AA IEC LR6 batteries not included TX141Wv2 Wind sensor 2 C IEC LR14 batteries not inc...

Page 18: ...e may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Caution The manufacturer is not responsible for a...

Reviews: