INACCURATE OUTDOOR TEMPERATURE/HUMIDITY  

 

 

The thermo-hygro sensor reads the environment. When the sensor reads high 

during the day but not at night it is a mounting problem. 

 

Side-by-side test: Bring the wind/thermo-hygro sensor in the house and place 

it next to the station for 2 hours.  

 

Compare indoor and outdoor temperature. The temperatures should be within 4 

degrees to be within tolerance. The humidity should be within 14% to be within 

tolerance.  

 

If the sensor reads correctly when next to the wind speed station then try a 

different location outside.  

 

Look for heat sources such as sunlight or reflected heat. 

 

OUTDOOR READINGS ARE STUCK OR OFL 

 

 

Check batteries. Overpowered or underpowered batteries can cause this 

reading. 

 

Replace sensor. 

 

INTERMITTENT SENSOR READINGS 

 

 

RF (radio frequency) communication may come and go occasionally.  This can be 

normal in some environments (e.g. moister climates).   

 

If a sensor goes out, please wait 2-4 hours for it to reconnect on its own.  Please 

be patience – these stations can reconnect on, after many hours out. 

 

RF (radio frequency) communication is not always 100% on.  

 

Certain temporary conditions can cause it to go out for a time (e.g. 100% 

humidity).  

  

If a miss happens: 

 

Hold the WIND button for 5 seconds to search for sensor. 

 

The units try for 20 minutes to reconnect. After 20 minutes, the sensor stops 

trying for an hour (to preserve battery life). After the 1-hour break, the sensor 

will start another 20-minute re-connect cycle.  

 

Distance/Resistance

 can cause loss of sensor signal. Avoid having more than 

one wall, window, tree etc., between the display and the sensor. UV coated 

windows may actually reflect the signal. Stucco walls will absorb the signal. 

 

Check

 batteries

. This is our primary warranty issue. 

 

SENSOR DRAINS BATTERIES QUICKLY 

 

 

Test a new set of alkaline batteries. Write down the date of installation and the 

voltage of the batteries. 

 

When the batteries fail, please note the date and voltage again. This is helpful in 

determining the problem. 

 

Check the distance and resistance between the sensor and station. Sensors at 

the end of the range may work while batteries are fresh but not after they drain 

a bit. 

 

Check for leaking batteries, which may damage the sensor. 

Summary of Contents for 327-1417BW

Page 1: ...e humidity Wind Speed 3 Inaccurate outdoor temperature humidity 4 Outdoor Readings are stuck or OFL 4 Intermittent Sensor Readings 4 sensor drains batteries quickly 4 Fahrenheit Celsius 5 HI LO Temper...

Page 2: ...rformance WEATHER STATION FACTORY RESTART The factory reset will return the wind speed station to its default settings This will clear all previous recorded history so you may want to write down data...

Page 3: ...s and the wind station 5 10 feet apart for 15 minutes to establish a solid connection 9 After 15 minutes place the remote sensors in appropriate shaded locations 10 Press and release the CH button to...

Page 4: ...ience these stations can reconnect on after many hours out RF radio frequency communication is not always 100 on Certain temporary conditions can cause it to go out for a time e g 100 humidity If a mi...

Page 5: ...TEMPERATURE HUMIDITY RECORDS Press and release the TEMP button to view individual HI LO readings Hold the MINUS button for five seconds to reset each individual value Individual readings will reset t...

Page 6: ...u need to contact customer support Check that your batteries are fresh in the thermo hygro sensor and the Wind speed station UNDERSTANDING WIND READINGS Current Wind Speed The current wind speed which...

Page 7: ...o arm the alert 2 Press the ALERTS button and the alert value will flash 3 Press the or buttons to set the alert value Hold to set quickly 4 Press ALERTS button to move to next alert Alert OFF 1 Alert...

Page 8: ...ve to the next item Note The warning values are not programmable You can only activate deactivate the frost or storm warning This station offers the option of active Frost and Storm alerts Simply acti...

Page 9: ...e sensor may be mounted from the bottom or side Use your own mounting pole Insert your own mounting pole into the sensor Tighten screws Optional Add on TX141TH BCH sensor To mount the sensor either us...

Page 10: ...o the wall by a metal mesh will cause interference Transmitting antennas from ham radios emergency dispatch centers airports military bases etc may cause interference Electrical wires utilities cables...

Page 11: ...e the or button to select the correct date Confirm with the SET button and move to F C Note The Day of the Week will set automatically when the year month and date are set 8 F will flash Press and rel...

Page 12: ...st forty day average pressure for increased accuracy The longer the Wind speed station operates in one location the more accurate the forecast icons will be Install fresh alkaline batteries with corre...

Reviews: