INTRODUCTION: 

 
The Color Forecast Station features manual set  time, date, weather 
forecast, indoor and outdoor temperature/humidity, with temperature 
alerts, and heat index and dew point, on a stylish, colorful, and easy to 
read display. Use the integrated USB charging port to charge your 
smartphone, camera or other device when the Forecast Station is 
plugged into a power outlet.

 

 

COLOR FORECAST STATION: 

 

THIS STATION LEARNS! 
Please allow 3-4 weeks for barometer calibration to generate an 
accurate forecast. 

 

 

 

SETUP INSTRUCTIONS STEP BY STEP: 

  

STEP 1:  

  Insert the 5-volt a/c power adapter into the designated area on the 

back of the Forecast Station.  

  Plug the a/c power adapter into a wall outlet for continuous backlight 

(ON/OFF), and dimmer feature.  
 

STEP 2: 

(optional battery operation)

 

  Remove battery cover from the 

Forecast Station: Slide tab down and 
pull out to remove the cover.  

  Insert 3 NEW AAA batteries (not 

included) into the back of the 
Forecast Station. Observe the 
correct polarity (see marking inside 
the battery compartment). 

  The Forecast Station will light up and 

show, indoor temperature, humidity 
and time. 

 

(Backlight will illuminate for 8 seconds when using only battery power 
with a press/release of the SNOOZE/LIGHT button.)

 

 

Do Not Mix Old and New Batteries 

 

Do Not Mix Alkaline, Standard, Lithium or Rechargeable 
Batteries 

 
 

STEP 3: 

  Ensure that the transmitter is within 10 feet of the 

Forecast Station. 

  Remove battery cover from transmitter: Slide the battery 

cover down and lift off the front. 

  Insert 2 NEW AA batteries into the TX141TH-B 

transmitter. Observe the correct polarity. 

  Within 3 minutes the Forecast Station will show readings 

in the Outdoor temperature area on the LCD. 

Note

: Use Alkaline batteries (or Lithium for temperatures 

below -28.8°C/ - 20°F). 
 

SEARCH FOR TRANSMITTER:

 

 

 

After the batteries are inserted, the forecast station will search for the 
outdoor temperature/humidity transmitter for 3 minutes. 

 

The antenna symbol  

 will flash during reception, and temperature 

display wi

ll be dashes “---“. 

 

The antenna symbol scroll during RF (radio frequency) 
synchronization. 

 

If synchronization fails once, the antenna will lose one bar. 

 

 

If synchronization fails twice, the antenna will lose two bars. 

 

 

If reception continuously fails to receive 5 times, the antenna symbol 
will be shown as .  

 

The antenna will show full display with successful RF 
(radio frequency) reception.  

 

TROUBLESHOOTING: 

 

 

If the outdoor temperature is not displayed after three 
minutes, hold the SENSOR SEARCH button on the 
forecast station for three seconds to search for 
outdoor transmitter.  

 

Next remove the battery cover from the TX141TH-B transmitter then 
press the TX button to send a signal. 

 

If it still does not receive the outdoor temperature, remove the a/c 
cord and batteries from both the forecast station and the transmitter 
for 15 minutes repeat setup instructions from step 1.

  

 

                                     

 

TIME/DATE: 

  
The SETTINGS button will move through the program 
menu and confirm settings.  
 

 

Set Time and Date: 

 
Hold the SETTINGS button for three seconds to enter time set mode. 

 

12/24-HOUR: The time format 

12H

 will flash, use the ARROW buttons 

to choose 12-hour or 24-hour time format and press the SETTINGS 
button to confirm and move to hour. 

 

HOUR: The 

Hour 

will flash, use the ARROW buttons to choose the 

hour, and press the SETTINGS button to confirm and move to 
minutes. 

 

MINUTES: The 

Minutes

 will flash, use the ARROW buttons to choose 

the minutes, and press the SETTINGS button to confirm and move to 
the year. 

 

YEAR: The 

Year

 will flash, use the ARROW buttons to choose the 

year, and press the SETTINGS button to confirm and move to the 
month. 

 

MONTH: The 

Month

 will flash, use the ARROW buttons to choose 

the month, and press the SETTINGS button to confirm and move to 
the date. 

 

DATE: The 

Date

 will flash, use the ARROW buttons to choose the 

date, and press the SETTINGS button to confirm and move to 
Fahrenheit/Celsius. 

 

FAHRENHEIT/CELSIUS:

 °F or °C

 will flash. Use the ARROW buttons 

to select Fahrenheit or Celsius. Press and release the SETTINGS 
button to confirm and exit the program menu. 

Note: 

When no buttons are pressed for ten seconds the forecast station 

will save the last change and default back to normal mode. 
 
 

Color Forecast Station

  

with USB Charging 

Model: CA85176 | Quick Setup Guide

 

Summary of Contents for CA85176

Page 1: ...bol scroll during RF radio frequency synchronization If synchronization fails once the antenna will lose one bar If synchronization fails twice the antenna will lose two bars If reception continuously...

Page 2: ...cord it came with Many USB cords are for data transfer only and cannot be used for charging Output 1A maximum current USB Do NOT overload USB port HEAT INDEX DEW POINT TEMPERATURE Heat Index Heat Ind...

Page 3: ...ocation over a period of time to generate an accurate personal forecast Please allow 3 to 4 weeks for barometer calibration IMPORTANT As the forecast station builds memory it will compare the current...

Page 4: ...y 5151 Thimens Blvd St Laurent Quebec H4R 2C8 CANADA STATEMENT This device complies with Industry Canada RSS 210 Operation is subject to the following two conditions 1 this device may not cause interf...

Page 5: ...radiofr quence de synchronisation Si la synchronisation choue une fois le symbole de l antenne perd une barre Si la synchronisation choue deux fois le symbole de l antenne perd deux barres Si la r cep...

Page 6: ...ervent qu au transfert de donn es et ne peuvent pas tre utilis s pour recharger l appareil Sortie courant USB de 1 A maximum NE PAS surcharger le port USB INDICE DE CHALEUR ET POINT DE ROS E Indice de...

Page 7: ...a station m t o mesure la pression atmosph rique toutes les douze minutes Une moyenne est tablie partir de ces mesures toutes les heures et tous les jours puis est sauvegard e dans une m moire non vol...

Page 8: ...POUR LE CANADA Cet appareil est conforme la norme CNR 210 d Industrie Canada Son fonctionnement est soumis aux deux conditions suivantes 1 cet appareil ne doit pas causer d interf rences 2 cet appare...

Reviews: