background image

 

 

 

ALARM TIME:

  

 

The TIME ALARM button moves you through alarm 
set mode and confirms settings. 
 

 

Set Time Alarm: 

 
In normal mode, press and release the TIME ALARM button once to 
show alarm time. Hold the TIME ALARM button for three seconds to 
enter alarm set mode. 

 

HOUR: The

 Hour

 will flash, use the ARROW buttons to set the hour, 

and press TIME ALARM button to confirm and switch to minutes.  

 

MINUTES: The 

Minutes

 will flash, use the ARROW buttons to set the 

minutes, and press TIME ALARM button to confirm. 

 

Press the SETTINGS button to return to normal mode 

Note: 

When no buttons are pressed for ten seconds the forecast station 

will save the last change and default back to normal mode. 

 
Activate/Deactivate Time Alarm: 

 

 

In normal mode, press and release the TIME ALARM button once to 
show alarm time. 

 

Press and release the TIME ALARM button repeatedly to turn 
ON/OFF alarm. The alarm icon   appears when alarm is activated. 

Note

: The alarm will ring for 2 minutes then turn off if no buttons are 

pressed. 

 
Snooze

 
When the alarm sounds press the HI/LOW/OFF

 

button to snooze the 

alarm for 10 minutes. The snooze option can be repeated three times.  
The alarm icon   will flash while the snooze feature is 
active. 

Note

: while the alarm sounds press any button 

except

 

the TIME ALARM button to turn the alarm off. 
 

BACKLIGHT:

 

 
A/C adapter: 

The backlight is on continuously when operating the 

Forecast Station with the 5-volt a/c adapter. 

Note: 

When the Adapter is NOT in use, the Hi/Low/OFF light feature is 

not available.

 

  

 

HIGH: 

The backlight is defaulted to HI at setup when the Adapter is in 

use.

 

 

LOW: 

Press and release the HI/LOW/OFF button to dim the backlight.  

 

 

OFF: 

Press and release the HI/LOW/OFF button again to turn the 

backlight off. Press and release the HI/LOW/OFF button again to return 
to full strength.

  

Note: 

When the backlight is off, press any button to activate the 

backlight for 10 seconds.

  

 
Battery power: 

When operating on battery power only,

 

press and 

release the any button and the backlight will show for 10 seconds. 

 

USB CHARGE PORT: 

 
The integrated USB charging port (on back) will charge your smart 
phone, camera or other device when the forecast station is plugged into 
a power outlet.  

Note:

 This is a power output (charging) port only. This 

port will not supply power to the Forecast Station. 

  Connect your existing USB charging cord for your 

external device to the USB charging port on the back 
of the Forecast Station to begin to charge. Charging 
times will vary.  

 

Note:

 

Check that your device will charge with the USB cord it 

came with.

 

Many USB cords are for data transfer only, and cannot be 

used for charging. 

 

Output

: 1A maximum current USB. Do NOT overload USB port. 

 

 

HEAT INDEX & DEW POINT TEMPERATURE:  

 
Heat Index: 

 
Heat Index combines the effects of heat and humidity. It is the apparent 
temperature of how hot it feels to a human being. As humidity increases, 
the body is unable to cool effectively. The temperature will feel warmer. 
 

View Heat Index:

 From a normal display, press the HEAT/DEW button 

once and Heat Index will show instead of the outdoor ambient 
temperature. 

Note:

 Heat index will be the same number as the 

temperature until the outdoor temperature is above 
26.7° C (80 degrees ° F).  

 
Dew Point Temperature:   

 
Dew Point Temperature is the saturation point of the air, or the 
temperature to which the air has to cool in order to create condensation. 
The higher the dew points, the higher the moisture content of the air at a 
given temperature. 

 
View Dew Point Temperature

: From a normal display, 

press the HEAT/DEW button twice and Dew Point will 
show instead of the outdoor ambient temperature. The 
words Dew Point will show near outdoor temperatures.  

Note:

 Dew Point is lower than the actual temperature. 

 

TEMPERATURE TREND ICONS:     

 
The indoor and outdoor temperature trend indicators will update every 
30 minutes or less. These trends represent temperature changes over 
the past three hours. 
 

Temperature rising more than 1°C/ 2°F in the past three  

             hours 

Temperature has 

not changed

 more than 1°C/ 2°F in the  

             past three hours.  

 Temperature falling more than 1°C/ 2°F in the past three  

              hours 

 

TEMPERATURE ALERTS: 

 
Press

 

and release

 the TEMP ALERT button to toggle 

between the temperature alerts. 

Hold

 the TEMP ALERT 

button to set individual high and low alerts. 
 
The bell icon indicates each alert that is active. 
 

 
The MAX TEMP button will turn a temperature alert ON. 
This button will increase an alert value in Temp Alert set 
mode. 

 
The MIN TEMP button will turn a temperature alert OFF. 
This button will decrease an alert value in Temp Alert 
set mode. 
 

One or all of the HI and LO temperature alerts may be set. 

 

Range for indoor temperature alert:  

    0°C to 50°C (+32°F to +122°F) 

 

Range for outdoor temperature alert:  

    -40°C to 60°C (-40°F to 140°F) 
 

Select Temperature Alert Values: 

 

Hold the TEMP ALERT button for five seconds to select and set 
temperature alert values. 

 

OUTDOOR HI

 alert will flash. Press the ARROW buttons to set the 

alert value, and press the TEMP ALERT button to confirm. Then 
press the TEMP ALERT button again switch to OUTDOOR LOW 
setting. 

 

OUTDOOR LO

 alert will flash. Press the ARROW buttons to set the 

alert value, and press the TEMP ALERT button to confirm. Then 
press the TEMP ALERT button again switch to INDOOR HI setting. 

Summary of Contents for CA85176

Page 1: ...bol scroll during RF radio frequency synchronization If synchronization fails once the antenna will lose one bar If synchronization fails twice the antenna will lose two bars If reception continuously...

Page 2: ...cord it came with Many USB cords are for data transfer only and cannot be used for charging Output 1A maximum current USB Do NOT overload USB port HEAT INDEX DEW POINT TEMPERATURE Heat Index Heat Ind...

Page 3: ...ocation over a period of time to generate an accurate personal forecast Please allow 3 to 4 weeks for barometer calibration IMPORTANT As the forecast station builds memory it will compare the current...

Page 4: ...y 5151 Thimens Blvd St Laurent Quebec H4R 2C8 CANADA STATEMENT This device complies with Industry Canada RSS 210 Operation is subject to the following two conditions 1 this device may not cause interf...

Page 5: ...radiofr quence de synchronisation Si la synchronisation choue une fois le symbole de l antenne perd une barre Si la synchronisation choue deux fois le symbole de l antenne perd deux barres Si la r cep...

Page 6: ...ervent qu au transfert de donn es et ne peuvent pas tre utilis s pour recharger l appareil Sortie courant USB de 1 A maximum NE PAS surcharger le port USB INDICE DE CHALEUR ET POINT DE ROS E Indice de...

Page 7: ...a station m t o mesure la pression atmosph rique toutes les douze minutes Une moyenne est tablie partir de ces mesures toutes les heures et tous les jours puis est sauvegard e dans une m moire non vol...

Page 8: ...POUR LE CANADA Cet appareil est conforme la norme CNR 210 d Industrie Canada Son fonctionnement est soumis aux deux conditions suivantes 1 cet appareil ne doit pas causer d interf rences 2 cet appare...

Reviews: