INDOOR HI

 alert will flash. Press the ARROW buttons to set the alert 

value, and press the TEMP ALERT button to confirm. Then press the 
TEMP ALERT button again switch to INDOOR LOW setting. 

 

INDOOR LO

 alert will flash. Press the ARROW buttons to choose the 

value, and press the TEMP ALERT button to confirm and exit. 

Note: 

After selecting temperature alert values use the next step to turn 

individual alerts ON or OFF.  
 

Temperature Alerts ON/OFF 

 

 

In normal mode, hold then release the TEMP ALERT button to toggle 
between: 

o

  Outdoor HI 

o

  Outdoor LO 

o

  Indoor HI 

o

  Indoor LO 

 

 

Press the MAX TEMP button to turn the selected alert ON. The alert 
icon   appears when alarm is activated. 

 

Press the MIN TEMP button to turn the selected 
alert OFF. 

 

Note:

 When no temperature alerts are set the 

Temperature Alert area will show ALERTS OFF. 
 

Temperature Alert Sounds: 

 

 

When temperature alert sounds the corresponding alert icon   will 
flash. 

 

The alert beeps once every minute, until the temperature is out of 
alert range. 

 

Press any button to stop alert. The alert symbol    will still show. 

 

Turn alert OFF:  In normal mode, hold and release the TEMP ALERT 
button to select the alert to turn off. With HI or LO alert selected, press 
the MIN button to turn that alert OFF. 

 

MIN/MAX TEMPERATURES:  

 
The Forecast Station will show the daily minimum and maximum 
temperatures each day starting at midnight (12:00 AM). The Forecast 
Station automatically resets the min/max temperatures at midnight 
(12:00 AM). 

  

 

View MIN data:  

Press and release the MIN TEMP 

button to view the minimum Indoor and Outdoor 
Temperatures.

   

 

Reset MIN data:  

Hold the MIN TEMP button for 5 

seconds and the Indoor and all Outdoor Minimum Temperatures will 
be reset. The temperature area will show dashes briefly then return to 
current temperatures.   

 

View MAX data:  

Press and release the MAX TEMP 

button to view the maximum Indoor and Outdoor 
Temperatures.

   

 

Reset MAX data:  

Hold the MAX TEMP button for 5 

seconds and the Indoor and all Outdoor Maximum 
Temperatures will be reset. The temperature area will show dashes 
briefly then return to current temperatures.      

 

WEATHER FORECAST ICONS: 

 
The Forecast Station predicts weather condition of the next 12-hours 
based on the change of atmospheric pressure with 70-75% accuracy. 

Note

: As weather conditions cannot be 100% correctly forecasted we 

are not responsible for any loss caused by an incorrect forecast. 

 

The forecast station samples the barometric pressure every twelve 
minutes. These samples are averaged hourly and daily then stored in 
nonvolatile memory.  

The three hour pressure icon change is based off of the last four 
average hourly readings.  
 

THIS STATION LEARNS! 
The forecast station calibrates barometric pressure based on its 
location over a period of time to generate an accurate, personal 
forecast. Please allow 3 to 4 weeks for barometer calibration.

 

IMPORTANT

: As the forecast station builds memory, it will compare the 

current average pressure to the past forty day average pressure for 
increased accuracy. The longer the forecast station operates in one 
location the more accurate the forecast icons will be. 

 

FORECAST TREND ICON:   

 
The forecast trend arrows in the upper right corner of the forecast 
display indicate the rising or falling pressure trend. 

 
Rising Pressure 

Falling Pressure 

 
The up trending arrow indicates the weather is improving. The down 
trending arrow indicates the weather may worsen. When there is no 
arrow the pressure is steady. 
 

LOW BATTERY:                                                                                                                                        

 

 

  When this icon 

  appears in the indoor (IN) reading section, replace 

the batteries in the Forecast Station.  

  When this icon 

 appears in the outdoor (OUT) readings section, 

replace the batteries in the outdoor transmitter.  
 

CARE AND MAINTENANCE:  

 

 

Do Not Mix Old and New Batteries 

 

Do Not Mix Alkaline, Standard, Lithium or Rechargeable 
Batteries 

 

Do not expose the forecast station to extreme temperatures, vibration 
or shock.  

 

Keep forecast station dry. 

 

Clean forecast station with a soft damp cloth. Do not use solvents or 
scouring agents. 

 

The forecast station is not a toy. Keep it out of reach of children. 

 

The forecast station is not to be used for medical purpose or for public 
information, but is determined for home use only. 

 

The specifications of this forecast station may change without prior 
notice. 

 

Improper use or unauthorized opening of housing will void the 
warranty. 

 

POSITION THE FORECAST STATION: 

 
Choose a location for the forecast station that is within range 
of the outdoor transmitter.  The forecast station has a built in 
base stand to sit on a table or desk.   

  Choose a location 6 feet or more from electronics such as 

cordless phones, gaming systems, televisions, 
microwaves, routers, baby monitors, etc., which can 
prevent signal reception.  

  Be aware of electrical wires and plumbing within a wall. 
  Best reception is achieved when the front or the back of the 

forecast station is facing the outdoor transmitter. This allows a larger 
portion of the antenna to receive a signal.  
 

POSITION THE OUTDOOR TRANSMITTER: 

 
Once the Forecast Station shows the outdoor temperature/humidity, 
place it and the transmitter in the desired locations and wait 
approximately 1-hour before permanently mounting the transmitter to 
ensure that there is proper reception. The transmitter should be 
mounted vertically, in a shaded, protected area, at least 6 feet from the 
ground to avoid damage and ensure accurate readings. The transmitter 
is water resistant, not waterproof and should not be placed anywhere it 
will become submerged in water or subject to standing water or snow. 
 
Choose a location for the transmitter that is within range of the Forecast 
Station and under an overhang for accuracy. 

 
 

Summary of Contents for CA85176

Page 1: ...bol scroll during RF radio frequency synchronization If synchronization fails once the antenna will lose one bar If synchronization fails twice the antenna will lose two bars If reception continuously...

Page 2: ...cord it came with Many USB cords are for data transfer only and cannot be used for charging Output 1A maximum current USB Do NOT overload USB port HEAT INDEX DEW POINT TEMPERATURE Heat Index Heat Ind...

Page 3: ...ocation over a period of time to generate an accurate personal forecast Please allow 3 to 4 weeks for barometer calibration IMPORTANT As the forecast station builds memory it will compare the current...

Page 4: ...y 5151 Thimens Blvd St Laurent Quebec H4R 2C8 CANADA STATEMENT This device complies with Industry Canada RSS 210 Operation is subject to the following two conditions 1 this device may not cause interf...

Page 5: ...radiofr quence de synchronisation Si la synchronisation choue une fois le symbole de l antenne perd une barre Si la synchronisation choue deux fois le symbole de l antenne perd deux barres Si la r cep...

Page 6: ...ervent qu au transfert de donn es et ne peuvent pas tre utilis s pour recharger l appareil Sortie courant USB de 1 A maximum NE PAS surcharger le port USB INDICE DE CHALEUR ET POINT DE ROS E Indice de...

Page 7: ...a station m t o mesure la pression atmosph rique toutes les douze minutes Une moyenne est tablie partir de ces mesures toutes les heures et tous les jours puis est sauvegard e dans une m moire non vol...

Page 8: ...POUR LE CANADA Cet appareil est conforme la norme CNR 210 d Industrie Canada Son fonctionnement est soumis aux deux conditions suivantes 1 cet appareil ne doit pas causer d interf rences 2 cet appare...

Reviews: