Timer Mode

-

1 second resolution

Count Down Timer

-

Quick set function (3, 5, 10, 15 and 45 minutes)

-

One user-define timer up to 23 hours 59 minutes 59 
seconds

 

Operation Mode

-

Countdown or repeat mode

Timer Sounds

-

Beep at last 5 seconds and

sounds for 2 seconds when count to zero

Altimeter Mode

-

1m or 3.28ft resolution

Measuring range

-

-702m to 9164m or -2303ft to 30065ft (Assume sea level 
is 1013.21 hPa/mbar and 0m)

Display range

-

-9164m to 9164m or

Accuracy

-

+/-50m or +/-164ft (Over temperature range -10.0  C to
60.0  C or 14.0  F to 140.0  F)

 -30065ft to 30065ft (Depends on the 

altitude reference setting)

Real Time Mode

-

Hour, minute, second, am, pm, month, day, day of week 
o r   b a r o m e t e r   p r e s s u r e   t e n d e n c y  d i s p l a y   ( S e l e c t a b l e  
between day of week)

Time System

-

12-hour or 24-hour format

Calendar System

-

Auto-Calendar pre-programmed from the year 2000 to 
2099

Alarm Mode

-

1 minute resolution

-

1 daily alarm and 1 date alarm

-

Hourly chime

Alarm Sounds

-

Sounds for 20 seconds at preset time of real time clock

Chronograph Mode

-

1/100 second resolution

Measuring Range

-

23 hours 59 minutes 59.99 seconds

Measuring Mode

-

10 lap memories

-

Recall lap memories and total time

7

.0 Specifications

Altitude Reference Setting

-

-9164m to 9164m or -30065ft to 30065ft 

Influence

- Minimum influence of temperature change on altitude

Conversion

- ICAO/ISA (Pressure to Altitude conversion)

Sampling Interval

- First 3 minutes: 1 second; after 3 minutes: 1 minute

Barometer Mode

- 0.1 hPa/mbar or 0.01 inHg resolution

Measuring range

- 300.0 hPa/mbar to 1100.0 hPa/mbar or 8.84 inHg to 32.44 

inHg 

Display range

- Same as measuring range

Pressure Tendency Setting

- 0.01 hPa/mbar resolution

- 0.00 hPa/mbar to 99.99 hPa/mbar

Compensation

- Temperature compensation

7

.0 Specifications ... 

continue

 

Sampling Interval

-

First 3 minutes: 1 second; After 3 minutes: 1 minute

Thermometer

-

0.1  C or 0.18  F resolution

Measuring range

-

-10.0  C to 60.0  C or 14.0  F to 140.0  F

Sampling Interval

-

First 3 minutes: 1 second ; After 3 minutes: 1 minute

Backlight

-

Electro-Luminescent (EL) backlight

Battery

-

Single 3V lithium battery (CR2032)

Battery Life

 

-

Approximately 1.5 year under the following conditions:

30 seconds alarm operation per day

5 seconds EL backlight operation per day

3 minutes sensor mode operation per day

Battery Low Detection

-

Battery voltage< 2.4 V +/- 0.2

Accuracy

-

+/- 1  C or +/-1.8  F (Over temperature range -10.0  C
to +60.0  C or 14.0  F to 140.0  F)

Summary of Contents for K2-100

Page 1: ...ale 5 3 Altimeter Mode Calibrate the Altimeter 5 4 Altimeter Mode Set the Altitude Alarm 5 5 Altimeter Mode Normal Altitude and Relative Altitude 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 5 6 Al...

Page 2: ...r K2 100 in a dry place when it is not in use 1 0 Introduction 1 3 2 4 2 0 The K2 100 Parts and Its Functions 3 0 Major Function Modes Time Keeping Altimeter and Barometer Mode Time Keeping Mode mode...

Page 3: ...art stop button to increase the number Press the lap reset button to decrease the number 15 gives a darker display 0 gives a lighter display After you set the time date display format and display cont...

Page 4: ...e lap number will be displayed at the right hand side of the display for 5 seconds as well as the lap time display on the bottom row of the display Then the chronograph starts running again automatica...

Page 5: ...ress the mode button to exit the setting sequence If no bu tton is pressed in the setting display for about 3 minutes the K2 100 will return to the Timer Mode automatically hour second minute Timer Co...

Page 6: ...meter Graph Display In the Altimeter Graph Display the 1st row of the display shows the altitude history graph of the last 24 hours T h e 2 n d r o w o f t h e d i s p l a y s h o w s t h e a l t i t...

Page 7: ...istory graph are recorded early than those on the right The flashing column of the history graph indicates which memory is displaying during the 24 hour memory reviewing 5 5 Altimeter Mode Normal Alti...

Page 8: ...M indicator starts flashing which indicates that the User Log Memory recording in progress Press the start stop button once again to stop the recording of the User Log Memory Free Record Display While...

Page 9: ...ld lap reset lap reset button Graph Scale Display 6 0 Barometer and its sub displays continue Barometric Graph Display 31 32 6 2 Barometer Mode Pressure History Graph Scale Pressure History Graph Scal...

Page 10: ...ory graph shows on the 1st row of the display T h e p r e s s u r e m e m o r y a n d te m p e r a t u r e s h o w o n the 2nd row of the display The time which recorded the memory shows on the 3rd ro...

Page 11: ...econds Measuring Mode 10 lap memories Recall lap memories and total time 7 0 Specifications Altitude Reference Setting 9164m to 9164m or 30065ft to 30065ft Influence Minimum influence of temperature c...

Reviews: