5 |
P a g e
MOUNTING: WHERE DO I MOUNT/POSITION MY SENSORS?
All of your sensors read independently to your station. This provides freedom to position each
sensor in the best location available.
LTV-W1 OR LTV-W2:
•
Place your wind sensor two times higher than any large object within 50 feet. Wind does not
pass through hard objects, it is distorted by them. If your sensor is too close you will
measure the air turbulence and not actual wind speed.
•
Place away from trees. Wind passing through trees moves slower than wind in open areas.
•
Mount your sensor in a vertical position with the wind cups on top.
•
Maximum transmission distance from your multi-sensor to your station, in open air is 400 feet
(121.92meters).
•
Use the included mounting bracket or your own mounting pole (no more than 1 inch outer
diameter to fit). Secure to the sensor with screws provided. Tighten the screws to snug (do
not over tighten).
•
General Wind Sensor mounting video:
http://bit.ly/wind_sensor_mounting
LTV-R3:
•
Mount your rain sensor in an open area for a more accurate rain count.
•
Placing the rain sensor on the ground provides the most accurate rainfall measurement as
there is no wind shear. Unfortunately, since insects think of rain gauges as personal hotels,
placing the sensor 3-6 feet above ground may deter the insects.
•
Be sure your rain sensor is not sitting in a depression that would prevent rain from draining
form the sensor properly.
•
Your rain sensor should be accessible to allow for periodic cleaning of leaves or other
debris that may clog the funnel.
•
Install the Rain sensor on a level platform that is stationary and has a direct line of sight to
your station.
•
Insert three mounting screws through the holes in the base of the rain sensor. Do not over
tighten.
•
Avoid other wireless rain sensors, as this can cause inaccuracy.
•
The maximum wireless transmission range to the rain station is over 400 feet (121 meters) in
open air, not including walls or floors.
•
General Rain Sensor mounting video:
http://bit.ly/Rain_SensorMounting
LTV-TH2:
•
Place your Thermo-Hygro sensor at least 6 feet off the ground.
•
For accurate temperature readings your sensor needs to be shaded from the sun in a well
vented area.
•
Mount your sensor vertically to allow moisture to drain out the bottom.
•
Preferred location is on a north facing wall under an eave or deck rail.
•
Avoid placing near a metal roof that will cause it to read high on sunny days.
•
Avoid other sources of heat such as soffit vents, and window or door frames.
•
For accurate humidity readings, avoid placement near vegetation and lakes or other bodies
of water when possible.