background image

 

 
The comp
 

 

 

 1 

 2 

 2 

 2 

 32 

f

 Mas

 Pow

 

 
IMPORTA

battery com
center and

not work:
 
STEP 1: 

C

 

STEP 2: 

 Unwi

 Plug 

hygro

 The 

c

 

STEP 3: 

In

 

STEP 4: 

In

 

STEP 5: 

 Insert th

 Once th

weather

 Within t

 

Note

: T

 

Do not

 

 

TEST: 

D

to simul

 
View Rain

 Press a

 With Wi

 Press a

 After 30

 

STEP 6: 

S

 
SETUP TR

If the trans
and start t
 

 
There are 
or MIN/MA
button to m

 
All items
5,978,73
 
Wind Se

 

lete owner’s ma

Wind Sens

TX23U-I

U-bolts for mas
Washers 
Nuts 
cable ties 

ft. cable (attache
st holder

 

wered by thermo

ANT:

 Make sure

mpartments.  

In

d the outdoor se

 

Complete initial 

nd the cable of 

the connector o

o transmitter. Th

cable should “cl

nsert two "AA" s

nsert two “AAA”

hree "AA" size b

he batteries are 

r icons, and air 

wo minutes, the

The station first r

press any butt

During these 15

late wind speed

n Data:

 After 15

and release the S

ind Gust showin

and release the 

0 Seconds the L

Set Time and Da

ROUBLESHOO

smitter data fails

he Setup proce

five function bu

AX button will ch

move to the nex

s, including Win

38; 6,076,044; &

ensor also Prote

anual is availabl

sor 

st holder 

ed) 

o-hygro sensor

 

e to observe the 

nserting the ba

ensors on a surf

setup on a table

the Wind senso

of the wind cable

he Wind sensor 

ick” into place. 

size batteries in

” size batteries i

batteries into the

installed, all seg

pressure value.

e Weather Cent

receives the tem

tons

 for 15 min

5 minutes, tip the

d/direction chang

5 minutes, if the 

SET/MODE but

ng, firmly press 

PLUS button to 

LCD will revert b

ate. See “

Progr

OTING:

   

s to display for a

edure again at S

uttons:  SET/MO

hange a value.  

xt step.  Exit the 

nd Sensor, are P

& 6,597,990 

ected under U.S

le at: 

http://www

Ra

T

 
 

 Base 

s

cover a
(pre-as

 

2 x Sc
Ancho

 Requir

(not in

correct polarity

tteries incorre

face with 5-10 fe

e with all compo

or.  

e into the socke

is powered by t

to Thermo-hygr

into the rain sen

e Professional W

gments of the L

. "- - -" will be sh

er will start rece

mperature, hum

utes. You will se

e rocker of the r

ges. After 15 m

Wind and Temp

tton firmly so W

the PLUS butto

toggle from Pre

back to Pressure

ram Menu

” belo

any of the outdo

Step 2 

ODE, 

+

, HISTOR

Hold the SET/M

programming m

Protected under 

S. Patent: 6,761

Professio

Model: WS-15

w.lacrossetechn

ain Sensor 

TX32U-IT 

 

sensor, funnel to

and battery cov

ssembled) 

rews  and Plast

rs 

res 2-AAA batte

cluded) 

SETUP INST

y when inserting

ctly may result

eet between ea

onents within 10

et of the Thermo

the Thermo-hyg

ro transmitter w

nsor with the co

Weather Center

LCD will light up

hown for outdoo

eiving data from

idity and wind in
ee the wind and

rain sensor to s

inutes you can v

perature/Humid

ind Gust is disp

on and the 24-ho

essure, 24-hour
e and Wind Spe

ow.

 

oor sensors with

RY, ALARM, an
MODE button un
mode at any tim

r U.S. Patents: 

,065; RE42,057

onal Weathe

516U-IT | Quick

ology.com/1516

T

op 

ver 

tic 

eries 

 

 Air

win

 

Wa

 

Mo

 Pla

 

Re
inc

 
 
 
 
 
 
 
 

TRUCTIONS ST

 batteries.  The 

t in permanent

ch sensor and t

0 feet of each ot

o-hygro transmit

gro transmitter.

ith correct polar

rrect polarity. 

 

r with the correc

 briefly and then

or data. 

m the transmitter

nformation then

d temperature d

imulate rain. Tu

view the rain da

dity are showing
played in place o

our or Total Rai

r Rain and Tota

eed. 

hin 15 minutes, 

Program Menu

d MIN/MAX.  Th

ntil the display f

me by pressing th

This pr

7

 

er Station 

k Setup Guide

6

 

 

Thermo-Hygro 

TX31U-IT

 

rflow cover (rem

nd sensor cable
all mount adapt

ounting screws

astic anchors fo

equires 2-AA ba

cluded) 

TEP BY STEP:

"+" markings o

t damage to the

the display. 

Onl

ther. 

 

tters to connect

rity. 

 

ct polarity. 

 

n display the tim

rs.  

 searches for th

ata within 2 min

urn the wind dire

ata.

 

 on the Weathe

of Wind Speed. 

n, should appea

l Rain. 

(“- - -“are displa

u: 

he SET/MODE

flashes to enter 

he ALARM butto

roduct offers:

Sensor 

 

move to plug in 

e) 

er 

or screws 
atteries (not 

n the batteries m

e units.

 During 

ly

 

use Alkaline

t the Wind senso

me as 12:00, the

he rain sensor. 

 

nutes.

 

ectional vane an

er Center, view t

 

ar in the 

Pressu

ayed), remove th

button will move

the program me

on.   

915MHz INSTA
wireless transm
developed by L
TRANSMISSIO
4.5 seconds!)  
outdoor data m
climatic variati

Professio

W

 Detacha

 Requires

included

must line up wit

the setup proce

e Batteries, rec

or to the Therm

e date as 1.1.05

nd spin the wind

the Rain data: 

ure area

.  

he batteries from

e through the pr
enu.  Press and

ANT TRANSMISSIO

mission technolog
LA CROSSE TECH

ON offers you imm

(Every 6.5 second

measured from the

ions in real-time!

 

onal Weather C

WS-1516U-IT 

 
 

ble base stand

s 3-AA batteries

 

th the diagrams 
ess, place the w

hargeable batt

o-

5, the 

d cups 

m all units for 10

rogram menu. T

d release the SE

ON is the state-of-

gy, exclusively de

HNOLOGY®. INST

ediate outdoor da

ds for rain!)  from 
e transmitters: fol

Center 

 

s (not 

inside the 

weather 

teries may 

0 minutes 

The PLUS 

ET/MODE 

-the-art new 

esigned and 

TANT 

ata (every 

all your 

low your 

Summary of Contents for WS-1516U-IT

Page 1: ...ctly may result eet between ea onents within 10 et of the Thermo the Thermo hyg ro transmitter w nsor with the co Weather Center LCD will light up hown for outdoo eiving data from idity and wind in ee the wind and rain sensor to s inutes you can v perature Humid ind Gust is disp on and the 24 ho essure 24 hour e and Wind Spe ow oor sensors with RY ALARM an MODE button un mode at any tim r U S Pate...

Page 2: ...of minimum data conds then the will be reset to th mode e fourth section imes to show th e when the Rain not be reset temperature nt in F or ºC Time display ve air pressure nHg or hPa or nd 24h rainfall in inch or mm Wind Chill in F or C temp alarm Low Low battery Indicato Wind direction e histogram 2 d a number from to the hour set the Hour If utes ons to set the M y Use PLUS bu ppears under th r...

Page 3: ... ce you move them ait a few minutes r center remove hermo hygro sen holder and be s positioned corre sensor elbow m hat takes time an 3 Display Modes y of Mode 1 or al Rain should he LCD will reve m current time a oing last 24 hou ue Total rain ref al Rainfall on the and placemen e intended moun e equates to an idity and receive eless range of th ction This inform o the port on the enter The rain ...

Page 4: ...or weather h or other obstru r down too tight ary If the gauge st 6 ft in the air to allow for peri year or stored i ain gauges in th omplete instruc gy com 1516 82 1610 w lacrossetechn cal support or 4 ers and nuts incl g The ideal mas t line down the m or Use the N S s that can crack the package T interfere with th rmo hygro sens s oks designed for cable at regular f or more is req est Higher is...

Reviews: