background image

 

 
Press and

Wind Spee
 

 
 

 

 
 
 
Rain Disp

In 

MODE 2

toggle from
 

 24-HOU

The day

 TOTAL 

total rai

   Note

: Yo

 
IMPORTA

have a wir
floors, ceil
 

 The 

t

cente

 The 

w

hardw
provid

 The 

w

cente

 
If the sens
moving the
displayed 

 

WIND

:  

 The 

W

 Caref

being

 

Strai

patie

 
 
 
 
 

 

Elbow

other

d release SET/M

ed. 

 

play: 

2

, press and rel

m Pressure, 24-

UR RAIN: The 2

y is not a fixed c

RAIN: Total rai

n. 

ou must start a 

ANT:

 

 

Ensure tha

reless range of 

3

ings, etc.) will re

thermo-hygro

 s

er. The thermo-h

wind sensor

 m

wired to the win

de power for the

wireless 

rain se

er. See the 

Con

sor wireless icon

e weather cente

after re-position

Wind sensor sho

fully thread the 

g pinched.  

ght mast holde

nce to undue.  

w mast holder

r and the Wind s

MODE button t

lease the PLUS

-hour Rain and T

24-hour rain refle

clock time meas

n will remain un

new history file 

at all of the sen

330-feet

. Keep 

educe the range

sensor measure
hygro sensor m

easures wind s
d sensor with a

e wind sensor. 

ensor

 sends the

nection Diagra

ns 

 drop from

er or the sensor
ning the sensors

ould be within 3

Wind Cable thr

er

: Be sure the 

: Double-check 

sensor. This is a

to toggle betwe

MODE 1:   

Wind Speed  
Outdoor Tem
Relative Pres

S button and the

Total Rain. Afte

ects the rain tha

surement.  It is l
ntil you manually

on the PC if yo

Mountin

sor data can be

in mind that the

e.  

es outdoor temp

ust be within the

peed, wind gust

 connector head

e data directly to

am

 below. 

 the display as 

rs closer and wa

s or the weathe

30 feet of the Th

ough the mast h

mast holder is p

that the Wind s

a secure lock th

een the display

            

mperature

ssure 

e 24-hour or Tota

er 30 Seconds th

at has fallen from

iterally an ongo

y reset this valu

u reset the Tota

g the sensors 

e received at the

330-foot 

rang

perature & humi

330-foot 

wire

t and wind direc

d that plugs into

o the weather ce

you move them

ait a few minutes

r center, remove

hermo-hygro sen

holder and be s

positioned corre

sensor, elbow m

hat takes time an

Display Modes

y of Mode 1 or 

            

              
                  
                 

al Rain, should 

he LCD will reve

m current time a

oing “last 24 hou

ue. Total rain ref

al Rainfall on the

 

and placemen

e intended moun

e equates to an

idity and receive

eless range of th

ction. This inform

o the port on the

enter. The rain s

m into their intend

s to see if the w
e all batteries fo

nsor to allow a s

ure the cable fit

ectly before lock

mast holder and 

nd patience to u

s: 

Mode 2: 

After 3

appear in the P

ert back to Pres

and back 24-ho

urs” timer.  

flects the rain fr

e weather statio

t of the weathe

nting locations b

n open-air scena

es the data from

he weather cent

mation is transm

e thermo-hygro 

sensor must be

ded locations, t

wireless icons 

or 15 minutes an

secure cable co

ts in the slot or 

king into the Win

straight mast ho

undue. 

30 Seconds the

Pressure area. P

ssure and Wind 

urs. This is not 

om time of disp

on to avoid inac

er center: 

before you drill 

ario with no obs

m the wind sens

ter.  

mitted to the the

sensor. The bat

 within the 

330-

he sensors may

 display again.

nd complete the

onnection with a

hole at the end,

nd sensor. This 

older are positio

e LCD will revert

MODE 

Wind G
Dew Po
24-hou

Press and releas

Speed. 

a midnight to m

lay set-up until 

curacies. 

mounting holes

structions.  Each

or, then sends t

rmo-hygro sens

tteries in the the

-foot 

wireless ra

y be too far from

 If the wireless 

e setup procedu

 

a drip loop.  

, designed to pr

is a secure lock

oned correctly b

t back to Pressu

2:

  

 

Gust 

oint Temperatur

r or Total Rain

se the PLUS bu

midnight measur

you manually re

. The outdoor s

h obstruction (ro

the data to the w

sor by the 32-fo

ermo-hygro sen

ange of the wea

m the weather ce

icons 

 are sti

ure from step 2.

revent the cable

k that takes time

before locking in

ure and 

re 

utton to 

rement. 

eset the 

ensors 

oof, walls, 

weather 

ot cable 

nsor 

ather 

enter.  Try 

ll not 

e from 

e and 

nto each 

Summary of Contents for WS-1516U-IT

Page 1: ...ctly may result eet between ea onents within 10 et of the Thermo the Thermo hyg ro transmitter w nsor with the co Weather Center LCD will light up hown for outdoo eiving data from idity and wind in ee the wind and rain sensor to s inutes you can v perature Humid ind Gust is disp on and the 24 ho essure 24 hour e and Wind Spe ow oor sensors with RY ALARM an MODE button un mode at any tim r U S Pate...

Page 2: ...of minimum data conds then the will be reset to th mode e fourth section imes to show th e when the Rain not be reset temperature nt in F or ºC Time display ve air pressure nHg or hPa or nd 24h rainfall in inch or mm Wind Chill in F or C temp alarm Low Low battery Indicato Wind direction e histogram 2 d a number from to the hour set the Hour If utes ons to set the M y Use PLUS bu ppears under th r...

Page 3: ... ce you move them ait a few minutes r center remove hermo hygro sen holder and be s positioned corre sensor elbow m hat takes time an 3 Display Modes y of Mode 1 or al Rain should he LCD will reve m current time a oing last 24 hou ue Total rain ref al Rainfall on the and placemen e intended moun e equates to an idity and receive eless range of th ction This inform o the port on the enter The rain ...

Page 4: ...or weather h or other obstru r down too tight ary If the gauge st 6 ft in the air to allow for peri year or stored i ain gauges in th omplete instruc gy com 1516 82 1610 w lacrossetechn cal support or 4 ers and nuts incl g The ideal mas t line down the m or Use the N S s that can crack the package T interfere with th rmo hygro sens s oks designed for cable at regular f or more is req est Higher is...