background image

 

POSITIONING:

 

Using 915MHz wireless transmission gives users little restriction on placement because all 
units can be positioned virtually anywhere within a 330 ft / 100 meters radius of the base 
station.  Please ensure that the cable included in this set meets your distance 
requirements (see accessories in the main user manual for adding extension cables). 

 

Important: 

Ensure all signals can be received and/or all cable distances meet with your 

requirements at the point of fixing particularly before you start drilling any mounting holes. 

 

Wind sensor 

Secure the main unit to the shaft of the mast holder using the single screw provided with 
the front of the sensor (marked E) facing in the East-West direction otherwise wind 
direction will not be accurate.  Now fix the entire unit to a suitable mast using the U-bolt, 
washers and nuts found in this set. 

 

Note:

 For best results mount the wind sensor onto a mast to allow the wind to freely travel 

from all directions to enable an accurate reading (ideal mast size should be from Ø 

5

/

8

” to 

1

1

/

4

”).  Ensure that the cable of the wind sensor meets your distance requirements 

 

Thermo-hygro Sensor 

To wall mount the thermo-hygro sensor, fix the wall holder onto the desired wall (2 screws 
are supplied), plug the sensor firmly into the wall holder and then carefully replace the rain 
cover back over the thermo-hygro sensor. 

 

Note:

 After mounting the units, should the weather data not be received, user may need to 

remove the batteries from all units and redo the set-up procedures after about 5 minutes. 

 

Rain sensor (optional) 

The rain sensor should be mounted horizontally about 2-3ft off from the ground (or higher) 
in an open area away from trees or other coverings to allow rain to fall naturally for an 
accurate reading. 

 

Note: 

For best results ensure the base is horizontal to allow maximum drainage of any 

collected rain 
 

 
 
 
 
 
 
 
 

Summary of Contents for WS-1913IT

Page 1: ...TIONAL Wireless transmission Self Emptying Rain sensor to weather centre Wireless transmission Thermo hygro transmitter to weather centre Weather Centre Wind Sensor Rain Sensor sold separately Thermo hygro Transmitter QUICK SET UP MANUAL PROFESSIONAL WEATHER CENTRE INITIAL SETUP ...

Page 2: ...door data 4 The Weather Centre will start receiving data from the transmitter The transmission reception icon will be blinking to indicate that the centre is trying to get the thermo hygro transmitter data The outdoor temperature humidity and wind data should then be displayed on the Weather Centre If this does not happen after 135 seconds the batteries will need to be removed from all units You w...

Page 3: ...installed there will be synchronization between weather centre and the transmitters At this time the signal reception icon will be blinking When the signal is successfully received by the Weather Centre the icon will be switched on If it is not successful the icon will not be shown in LCD This allows you to see whether the last reception was successful icon on or not icon off Short blinking of the...

Page 4: ...its all units need to be reset by following the setup procedure This is because the thermo hygro sensor will assign a random security code at start up and this code must be received and stored by the weather centre in the first several minutes of power being supplied to it HOW TO INSTALL AND REPLACE THE BATTERIES IN THE WEATHER CENTRE The Weather Centre works with 2 x C IEC LR14 1 5V batteries Whe...

Page 5: ...er on the unit Note When changing batteries in any of the units all units need to be reset by following the setting up procedure This is because the thermo hygro sensor and rain sensor optional assign a random security code at start up and this code must be received and stored by the Weather Centre in the first 135 seconds of power being supplied to it Note The stored history records will not be r...

Page 6: ... Mode 2 displayed will be shown for 30 seconds Then it will return to normal display Press to activate the reset mode when MAX or MIN record is shown key In display Mode 1 press to toggle the date weekday date Indoor temp or sec In display Mode 2 press to toggle the Relative Pressure 24 hour rainfall and Total rainfall if there is a rain sensor optional Press to adjust increase the level of differ...

Page 7: ...whether the last reception was successful ON icon or not OFF icon On the other hand the short blinking of the icon shows that a reception is being done at that time Wind speed gust in mph km h m s Calendar indoor temperature seconds display Weather tendency indicator Time display Air pressure history histogram Outdoor relative humidity in Weather forecast Icon Relative air pressure 24 hr rainfall ...

Page 8: ...w the rainfall data press the key after entering Mode 2 display Wind gust icon Dew point icon Rainfall icon In Mode 2 this reception icon is showing the condition of the reception of the signal from Rain sensor only if a rain sensor is being used Wind speed icon Outdoor temp icon Rel Air Pressure icon In Mode 1 this reception icon is showing the condition of the reception of the signal from Thermo...

Page 9: ...nd nuts found in this set Note For best results mount the wind sensor onto a mast to allow the wind to freely travel from all directions to enable an accurate reading ideal mast size should be from Ø 5 8 to 11 4 Ensure that the cable of the wind sensor meets your distance requirements Thermo hygro Sensor To wall mount the thermo hygro sensor fix the wall holder onto the desired wall 2 screws are s...

Page 10: ...cedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged EJMA1913T910 Printed in China ...

Reviews: