4. Wait 15 minutes to allow both the indoor and outdoor

temperatures are shown on the indoor temperature
station.

5. The indoor temperature station should now show: "-:- -

" in the TIME LCD, and temperatures in the INDOOR
and OUTDOOR LCD's.

II. TIME

A. SETTING THE TIME
1. Press and hold the "SET" button for 5 second,  "12h"

will appear in the TIME LCD.

2. Press and release the "MIN/MAX" button to select either

12h time (am/pm) or 24h time

3. Press and release the "SET" button 2 times, the hour

will flash in the upper left corner.

4. Press and release the "MIN/MAX" button to set the hours
5. Press and release the "SET" button to move to the

GB

P.6

GB

P.7

GB

P.8

GB

SET

TIME

INDOOR

OUTDOOR

2

433 MHz

CH

MIN/MAX

RESET/+

SET

CH

MIN/MAX

RESET/+

P.9

+

SIZE AAA

+

SIZE AAA

Battery cover

Battery 
compartment

DETAILED SETUP GUIDE

I. BATTERY INSTALLATION

A. REMOTE TEMPERATURE SENSOR
1. Remove the mounting bracket.
2. Remove battery cover
3. Observing the correct polarity,

install 2 AAA batteries-make
sure they do not spring free, or
start-up problems may occur.
Replace cover.

B. INDOOR TEMPERATURE STATION

Note

:  After the batteries are installed, DO NOT press any

buttons. This may interfere with the signals, causing
temperatures to register incorrectly.

1. Remove the battery cover on the backside.  To do this,

push up and pull out.

2. Observing the correct polarity, install 2 AAA batteries.
3. Replace battery cover.

minute setting

6. Press and release the "MIN/MAX" button to set the

minutes.

7. Press and release the "SET" button to activate the clock.

Note

:

When in 12h mode, there is only a "PM" display,

which appears under "TIME."  If there is no display here it
is AM.  Make sure you set the time accordingly.

III. UNITS OF TEMPERATURE MEASURE

A. SELECTING UNITS OF MEASUREMENT
1. Press and hold the "SET" button for 5 second until "12h"

or "24h" appears in the TIME LCD.

2. Press and release the "SET" button again, "˚F" will

appear in the TIME LCD.

3. Press and release the "MIN/MAX" button to shift

between ˚F and ˚C.

4. Press and release the "SET" button twice to activate

settings.

IV. FEATURES

A. MINIMUM AND MAXIMUM TEMPERATURES
1. Press and release the "MIN/MAX" button,  "MIN"

appears in the temperature LCD's and the recorded
minimum temperatures are displayed.

2. Press and release the "MIN/MAX" button to toggle to

the maximum temperatures. The time of occurrence of
the value for outdoor temperature will also flash.

B. RESETTING THE MINIMUM AND MAXIMUM

TEMPERATURES

1. To reset both the minimum and maximum temperatures-

press and hold the "RESET/+" button for 4 seconds.

C. ADDING ADDITIONAL REMOTE TEMPERATURE

SENSORS (OPTIONAL)

1. The WS-7013U is able to receive signals from 3 different

remote temperature sensors. Following are some brief
instructions for the basic set-up of remote temperature
sensor units with the WS-7013U. These extra sensors
can be purchased through the same dealer as this unit,
or by contacting La Crosse Technology directly.  A TX2U
and TX6U will monitor temperature only, a TX3U will
monitor temperature and display the temperature on its
LCD, and the TX3UP will monitor the temperature via a
probe for use in pools, spas, etc.

Note

:  When setting up multiple units it is important to

remove the batteries from all existing units in operation,
then to insert batteries first into all the remote temperature
sensor units, and in numeric sequence.  Second, install
batteries into the indoor temperature station.  Transmission
problems will arise if this is not done correctly and if the
total time for set-up exceeds 6 minutes.
2. It is necessary to remove the batteries from all units

currently in operation.

3. Remove the battery covers to all remote temperature

sensor units.

4. Place all remote temperature sensor units in a numeric

sequential order.

5. In sequential order, install batteries (follow the same

REMOTE 

TEMP. TRANSMITTER

433 MHz

+

SIZE AAA LR3

+

SIZE AAA LR3

Battery cover

Battery compartment

Summary of Contents for WS-7013BZ

Page 1: ...ditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Freq 433 92 MHz La Crosse Technology Made in China WS 7013U FCC ID OMO 01RX Receiver OMOTX6U transmitter SET TIME INDOOR OUTDOOR 2 433 MHz CH MIN MAX RESET Contents Language Page English 2 French 17 Spanish 32 R ...

Page 2: ...please retry the set up as stated above After both indoor and outdoor temperatures are displayed for 15 minutes you can place your remote temperature sensor outdoors and set your time The remote temperature sensor should be placed in a dry shaded area The remote temperature sensor has a range of 80 feet Any walls that the signal will have to pass through will reduce distance An outdoor wall or win...

Page 3: ...nd release the SET button again F will appear in the TIME LCD 3 Press and release the MIN MAX button to shift between F and C 4 Press and release the SET button twice to activate settings IV FEATURES A MINIMUM AND MAXIMUM TEMPERATURES 1 Press and release the MIN MAX button MIN appears in the temperature LCD s and the recorded minimum temperatures are displayed 2 Press and release the MIN MAX butto...

Page 4: ...ology com Problem The LCD is faint Solution Replace batteries Problem No outdoor temperature is displayed Solution 1 Remove all batteries reinsert into remote temperature sensor first and then into the indoor temperature station 2 Place remote temperature sensor closer to the indoor temperature station 3 Be sure all batteries are fresh 4 Place remote temperature sensor and indoor temperature stati...

Page 5: ...ts covered by this warranty Before sending the Weather Station in for repairs contact La Crosse Technology The Weather Station will be repaired or replaced with the same or similar model Proof of purchase must be included if it is determined that the weather station should be returned to La Crosse Technology LA CROSSE TECHNOLOGY WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OT...

Page 6: ...qu à ce que les heures correctes s affichent Remarque Dans le mode 12h mode un PM est affiché sous le mot TIME HEURE l après midi Le matin AM rien ne s affiche b Quand l heure correcte s affiche appuyer une fois sur SET SET TIME INDOOR OUTDOOR 2 433 MHz CH MIN MAX RESET Fig 1 F F P 19 F P 20 F P 21 P 18 MONTAGE RAPIDE Conseil Utiliser des piles alcalines de bonne qualité et éviter les piles rechar...

Page 7: ...UM 1 Pour réenclencher les températures minimum et maximum Appuyer sur RESET pendant 4 secondes C ADDITION DE CAPTEURS DE TEMPERATURE A DISTANCE EN OPTION 1 Le WS 7013U peut recevoir les signaux de 3 capteurs différents Instructions pour le montage de base des capteurs à distance avec le WS 7013U ces capteurs supplémentaires peuvent s obtenir auprès du vendeur de cet appareil ou en contactant La C...

Page 8: ...est fabriqué pour être exact au degré près dans des conditions normales il est donc possible que les deux appareils affichent jusqu à 2 degrés de différence Cependant cette différence peut être amplifiée par le fait que les deux appareils sont conçus pour fonctionner dans des environnements différents Le capteur intérieur est moins sensible aux courants d air ambiants en raison de l effet protecte...

Page 9: ...La Crosse technology sans délai Avant d envoyer le poste météo pour réparation contacter La Crosse technology Le poste météo sera réparé ou remplacé par un modèle identique ou similaire En cas de retour chez La Crosse Technology la station météo doit être accompagnée du ticket de caisse LA CROSSE TECHNOLOGY DECLINE TOUTE RESPONSABILITE POUR TOUT DOMMAGE ACCESSOIRE SUBSEQUENT PUNITIF AU AUTRE ASSOC...

Page 10: ... temperatura interior 4 NO PRESIONE NINGUNA TECLA POR 15 MINUTOS En este punto la Estación de temperatura interior y el sensor remoto de temperatura empezarán a hablarse el uno al otro y presentarán ambas temperaturas la interior y la del aire libre Si la Estación interior de temperatura no despliega ambas temperaturas después de 15 minutos reintente la puesta en funcionamiento como se explicó ant...

Page 11: ...as spas etc Note Cuando esté poniendo en funcionamiento múltiples unidades es importante que quite las baterías de todas las unidades existentes en operación luego inserte primero las baterías en todos los sensores remotos de temperatura y en secuencia numérica Después instale las baterías en la Estación de temperatura interior Problemas de transmisión pueden presentarse si esto no es hecho correc...

Page 12: ... de la cubierta o el calor radiante Adicionalmente el mayor rango del sensor de temperatura al aire libre requiere una curva de calibración diferente que el rango interior El error es usualmente mayor en los extremos de un rango haciendo difícil comparar diferentes rangos con diferentes curvas Bajo condiciones que no sean de laboratorio es difícil compensar los anteriores factores y obtener una co...

Page 13: ...hos por contrato específicos Puede ser que usted también tenga derecho a otros derechos específicos de su Estado Algunos Estados no permite la exclusión de daños y perjuicios consecuenciales o incidentales por lo tanto puede ser que la exclusión de limitación arriba en mención no sea aplicada en su caso Para el trabajo de la garantía reparaciones etc asistencia técnica o datos de información y dir...

Reviews: