background image

 

10

2.  Press and hold the SET button for 5 seconds. 
3.  The record is now reset and will show the current time in the TIME LCD and current indoor 

temperature and humidity in the INDOOR LCD. 

 

T o reset the OUTDOOR records: 
1.  Press and release the OUT/MIN button to select the record you wish to reset, either MAX or MIN 
2.  Press and hold the SET button for 5 seconds. 
3.  The record is now reset and will show the current time in the TIME LCD and current outdoor 

temperature and humidity in the OUTDOOR LCD. 

 

V. MOON 

PHASE 

There are 12 moon phases shown on the indoor weather station; the black portion signifies the portion of the 
moon visible in the sky. Thus, when the moon icon is all black, it is a full moon.

 

 

VI.  VIEWING THE CURRENT, MAXIMUM AND MINUMUM DEW POINT 

 

To view the current dew point: 

1.  Press and hold the OUT/MIN button for 5 seconds.   
2.  The OUTDOOR LCD will switch to show the dew point (DEW POINT will be visible in the upper 

left corner of the OUTDOOR LCD). 

 

To view the maximum and minimum dew point readings: 

1.  Press and release the OUT/MIN button. 
2.  The maximum or minimum value along with the time and 

date it was recorded will be displayed (MAX or MIN will be 
displayed below the words DEW POINT in the OUTDOOR 
LCD). 

3.  After 30 seconds the display will automatically go back to 

the normal display mode showing the current dew point 
reading. 

 

To reset the maximum or minimum dew point record: 
 

While viewing either the maximum or minimum dew point record: 
1.  Press and hold the SET button for 5 seconds. 
2.  The record will now be reset and show the current time in the TIME LCD and dew point reading in 

the OUTDOOR LCD. 

 

To return to the outdoor temperature/humidity viewing mode: 

1.  Press and hold the OUT/MIN button for 5 seconds. 
2.  The OUTDOOR LCD will switch back to show the outdoor temperature and humidity (DEW 

POINT will no longer be visible in the upper left corner of the OUTDOOR LCD). 

 

VII.  WIND SPEED, WIND CHILL, MINIMUM AND MAXIMUM VALUES 

In the WIND SPEED LCD you can view the current wind speed and 
gust.  The wind speed is updated every 128 seconds with the average 
wind speed of that time being displayed.  The gust display is the 
highest gust for the last 128-second period. 
 
To view the current wind chill: 

1.  Press and release the WIND/RAIN/SNZ button. 
2.  The wind chill value will display at the bottom of the WIND SPEED LCD. 

 

To view the maximum and minimum wind/wind chill values: 

1.  Press and hold the WIND/RAIN/SNZ button for 3 seconds. 
2.  The WIND SPEED LCD will now show the maximum wind. 
3.  Press and release the WIND/SNZ button again. 

Summary of Contents for WS-9046U

Page 1: ...WS 9046U Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Page 2: ...y and Month 6 7 Setting the Snooze 7 Setting the Temperature Format 7 Setting the Unit of Rainfall 7 Setting the Forecast Sensitivity 7 8 Features Weather Forecast Icons and Tendency Arrows 8 9 Indoor...

Page 3: ...dity sensor Figure 2 3 One TX15U wind speed sensor Figure 3 4 Mounting hardware 5 Instruction manual and warranty card OPTIONAL SENSOR PURCHASE SEPERATELY Rain Sensor for rainfall information Figure 1...

Page 4: ...nits for 10 minutes 5 Place the batteries into the remote temperature humidity sensor first then into the indoor weather station 6 DO NOT PRESS ANY BUTTONS FOR 15 MINUTES In this time the indoor weath...

Page 5: ...Liquid Crystal Display will flash Within 15 seconds the indoor temperature indoor relative humidity and the weather icons sun and clouds will be displayed If not remove batteries for 10 seconds and re...

Page 6: ...ow in the TIME LCD and the number setting will flash 3 Press and release the SET button again 4 The time zone will flash in the DATE LCD 5 Press and release the ALM button to select your time zone Not...

Page 7: ...ontrol Time This method requires you to do nothing except wait for the signal to be received and to select a time zone Reception usually takes approximately 10 minutes during optimal conditions The be...

Page 8: ...e SET button to confirm and advance to the temperature format setting XI SELECTING F OR C 1 Press and hold the SET button for 5 seconds 2 LCD will show in the time LCD and the number setting will flas...

Page 9: ...floor In areas where the weather is not largely affected by the change of air pressure the sensitivity setting should be set to 1 In areas where the air pressure changes more rapidly such as coastal...

Page 10: ...ECORDS The WS 9035U keeps a record of the MINIMUM and MAXIMUM temperature and the time and date of their occurrence for both the indoor and outdoor modes A VIEWING THE INDOOR TEMPERATURE RECORDS 2 Pre...

Page 11: ...yed below the words DEW POINT in the OUTDOOR LCD 3 After 30 seconds the display will automatically go back to the normal display mode showing the current dew point reading To reset the maximum or mini...

Page 12: ...e following pages is a list of the Beaufort Scale and the wind speeds it corresponds to Wind Speed fort Number or Force mph km hr knots Description Effects Land Sea 0 1 1 1 Calm Still calm air smoke w...

Page 13: ...rs overhanging crests sea becomes white with foam heavy rolling reduced visibility 11 64 72 mph 103 117 kph 56 63 knots Violent Storm Extensive widespread damage Large waves 9 14 meters white foam vis...

Page 14: ...infall is accumulated rainfall volume from the commencement of measurement which is equivalent to the Max rainfall shown in the current rainfall mode To reset the maximum rainfall measurements 1 Press...

Page 15: ...obstacles such as walls concrete and large metal objects can reduce the range Place both units in their desired location and wait approximately 15 minutes before permanently mounting to ensure that t...

Page 16: ...the remote wind speed sensor onto the bracket making sure to lock it in place C MOUNTING WITH THE U SHAPED BOLT 1 Use the U shaped bolt provided and thread it through each of the holder holes 2 Fix th...

Page 17: ...remote temperature humidity sensor and indoor weather station in position so the straight line signal is not passing through more than two or three walls Problem Temperatures do not match if units are...

Page 18: ...nal date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse T...

Page 19: ...hnical support or information contact La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 Fax 608 796 1020 e mail support lacrossetechnology com warranty work sales lacrossete...

Reviews: