background image

 

15

 

 

WEATHER FORECAST AND WEATHER TENDENCY: 

 

WEATHER FORECASTING ICONS: 

There are 4 weather icons in the fourth section of LCD that can be displayed in any of the following combinations: 

 
 
 
 

         

Sunny           Cloudy with sunny intervals         Cloudy      

                 Rainy

  

 

 

 

 

  

For every sudden or significant change in the air pressure, the weather icons will update accordingly to represent the 
change in weather. If the icons do not change, then it means either the air pressure has not changed or the change has 
been too slow for the intelligent weather station to register. However, if the icon displayed is a sun or rainy, there will be 
no change of icon if the weather gets any better (with sunny icon) or worse (with rainy icon) since the icons are already 
at their extremes. 

 

The icons displayed forecasts the weather in terms of getting better or worse and not necessarily sunny or rainy as 
each icon indicates. For example, if the current weather is cloudy and the rainy icon is displayed, it does not mean that 
the product is faulty because it is not raining. It simply means that the air pressure has dropped and the weather is 
expected to get worse but not necessarily rainy. 

 

The change of weather forecast icon is in accord to the relationship between current relative pressure and the pressure 
change since last three hours.  

 

If the weather is changing, both old weather icon and new weather icon will be shown with weather tendency indicator 
(animated arrows). If the weather has not changed within 6 hours, only the new weather icon in the middle display will 
be shown. 

 

Examples of changing weather icons: 

 
 
 

Note:

 

After initial set up of the intelligent weather station with the setting of the relative value, readings for weather forecasts 
should be disregarded for the next 12-24 hours. This will allow sufficient time for the intelligent weather station to collect 
air pressure data at a constant altitude and therefore result in a more accurate forecast. 

 

If the intelligent weather station is moved to another location significantly higher or lower than its initial standing point 
(for example from the ground floor to the upper floors of a house), set again the relative air pressure value, and discard 
the weather forecast for the next 12-24 hours. By doing this, the intelligent weather station will not mistake the new 
location as being a possible change in air-pressure when really it is due to the slight change of altitude.  

 

AIR PRESSURE TENDENCY INDICATOR 

The air pressure tendency indicators are located on the left side of the air pressure display, below the weather icons, 
and they work independently from the weather forecast icons. The air pressure tendency indicator pointing upward or 
downward directions is displayed based on comparing the difference of the air pressure recorded during a full hour time 
frame. 

 

Note:

 

 

A single air pressure tendency indicator will point upward or downward when the difference in air pressure 
registered is between 0.03 and 0.09 inHg (1 and 3hPa) within 4 hours. 

 

Two air pressure tendency indicators pointing upward or downward will be displayed when the air pressure 
difference has increased or decreased by 0.09 inHg (3hPa) or more within 4 hours.   

 
 

Summary of Contents for WS-9119U

Page 1: ...t of all its features FEATURES The Intelligent Weather Station WWVB Radio controlled time with manual setting option WWVB reception ON OFF user selectable 12 24 hour time display Time zone option 12 h...

Page 2: ...et up as stated above After all information has been displayed for 15 minutes you can place your sensors outdoors and set your time Important Notes on Set up and Operation The remote temperature humid...

Page 3: ...and stored by the intelligent weather station in the first 3 minutes of power being supplied to it BATTERY CHANGE It is recommended to replace the batteries in all units on an annual basis to ensure o...

Page 4: ...rs signal for all channels Combined with the set key to re detect a new transmitter in displayed channel Stop the alarm during the time alarm or weather alarm ringing Back light on MAX key Display MAX...

Page 5: ...displaying the information for time and date moon phase indoor data weather forecast air pressure air pressure history outdoor data intelligent weather information display Outdoor temperature in F or...

Page 6: ...set to view time as 12 24 hour format The default time display mode is 12h To set to 24h time display 1 Use the MAX or MIN key to toggle the value 2 Confirm with the SET key and enter the Time Zone s...

Page 7: ...month setting The month starts flashing 4 Use the MAX or MIN key to set the month 5 Press the SET key again to confirm and to enter the date setting mode The date starts flashing 6 Use the MAX or MIN...

Page 8: ...o improve The relative air pressure can be manually set to another value within the range of 28 35 to 30 72 inHg 960 1040 hPa or 720 781 mmHg for a better reference 1 The current relative pressure val...

Page 9: ...an be changed when pressing and holding the ALM DATA key for approximately 4 seconds LOW indoor temperature alarm HIGH indoor temperature alarm LOW outdoor temperature alarm HIGH outdoor temperature a...

Page 10: ...setting there are optional sub settings which can be set individually Note The outdoor temperature alarm can only be set for channel 1 transmitter To set the LOW outdoor temperature alarm default OFF...

Page 11: ...ALM DATA key to enter the HIGH indoor humidity alarm setting HIGH INDOOR HUMIDITY ALARM Note Within the HIGH indoor humidity alarm setting there are optional sub settings To set the HIGH indoor humidi...

Page 12: ...flashing 2 Use the MAX or MIN key to set the alarm value 3 Press the SET key to confirm and enter the LOW air pressure alarm setting IV If no HIGH outdoor humidity setting is needed please press the...

Page 13: ...alarm is set to 78 F 25 C and the current value moves to 78 F 25 C the alarm will be activated if it has been enabled Now when the temperature drops to 77 9 F 24 9 C or below and thereafter again inc...

Page 14: ...icon press the ALM DATA key Additionally the trigged alarm value and time will then be displayed briefly for 2 seconds on the bottom part of the weather station LCD If more than one Weather Alarm occu...

Page 15: ...new weather icon in the middle display will be shown Examples of changing weather icons Note After initial set up of the intelligent weather station with the setting of the relative value readings fo...

Page 16: ...ch change 1 2 3 4 5 6 7 8 the odd values are not shown on the vertical axis but can be determined shows in inches of mercury inHg how high or low the past air pressure was as compared to the current o...

Page 17: ...X data will be displayed as following sequences 1 MAX or MIN outdoor temperature data with time and date of recordings Data will flash 2 MAX or MIN outdoor humidity data with time and date of recordin...

Page 18: ...he CH key for 3 seconds outdoor reception signal will show next to channel display To re learn the CURRENT selected channel 1 Press and hold the SET key while pressing the CH key outdoor reception sig...

Page 19: ...nd the air pressure The intelligent weather station will automatically display the following information Minimum temperature of the day Maximum temperature of the day Time frame for the weather foreca...

Page 20: ...will be show when a specific weather event happened that has been calculated by the unique algorithm of the intelligent weather station REMOTE TEMPERATURE HUMIDITY SENSOR 433MHZ RECEPTION CHECK The o...

Page 21: ...s all system units have to be reset see Setting up POSITIONING THE INTELLIGENT WEATHER STATION The intelligent weather station has been designed to hang on a wall or free standing For Free standing Si...

Page 22: ...s this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy SPECIFICATIONS Temperature measuring range Indoor 14 F to 139 8 F with 0 2 F resolution 10 C to 59 9 C with...

Page 23: ...La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of...

Page 24: ...r chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in t...

Reviews: