background image

 

17

 

 

COMFORT LEVEL INDICATOR: 

Dry 

:

 

the “Dry” indicator will appear when the relative humidity range is lower than 45%.  

Comfort 

:   the “Comfort” indicator will appear when the relative humidity range is between 45% and 65% and the 

temperature range is between 68ºF and 78.6ºF (20.0ºC and 25.9ºC). 

Wet

 

:  the “Wet” indicator will appear when the relative humidity range is higher than 65%. 

 
 
 

 
 

HAPY/SAD FACE COMFORT LEVEL INDICATOR: 

 (happy face)  :   A happy face icon “

” indicating a temperature level between 68ºF and 78.6ºF (20°C and 25.9°C) 

and relative humidity reading between 45% and 65%.  

 (sad face) 

:  A sad face icon “ ” indicating any value outside the comfortable range.  

 

OUTDOOR TEMPERATURE AND HUMIDITY: 

 
 
 
 
 
 
 

The seventh LCD section can show the outdoor temperature, the reception indicator, the minimum or maximum 
reading. A number in the bottom part will also be shown if more than one transmitter has been used. 

 

TOGGLING BETWEEN MIN/MAX INDOOR AND OUTDOOR RECORDINGS:

 

To toggle between the current, minimum and maximum data and the times they were recorded, press the MIN/- key for 
viewing the minimum values, and press the MAX/+ key for viewing the maximum values (shown in MIN or Max 
displays). 

 

When pressing the MIN/- or the MAX/+ key, the MIN and the MAX data will be displayed as following sequences: 
1. 

MAX or MIN outdoor temperature data with time and date of recordings. Data will flash 

2. 

MAX or MIN outdoor humidity data with time and date of recordings. Data will flash 

3. 

MAX or MIN indoor temperature data with time and date of recordings. Data will flash 

4. 

MAX or MIN indoor humidity data with time and date of recordings. Data will flash 

5. 

Return to current indoor and outdoor data. 

 

TO VIEW THE MIN/MAX DATA FROM DIFFERENT TRANSMITTERS 

MIN/MAX data from other transmitters can only be displayed if there is more than 1 transmitter used. 

1. 

To toggle between transmitters, press the CH key: 
Once to show transmitter 2 
Twice to show transmitter 3 
Three times to return to transmitter 1 

2. 

While the outdoor MIN/MAX humidity and temperature date is being displayed, press the CH key. The display will 
toggle between the different channels MIN/MAX data.  

 

Note: 

 

For example, when the MIN outdoor temperature data is displayed and the MAX/+ key is pressed, MAX data outdoor 
temperature will be displayed. If the MAX outdoor temperature data is displayed and the MIN/- key is pressed, MIN 
outdoor data will be displayed.  

 

While MIN/MAX data is displayed, the channel can be changed by pressing the CH key. 

 
 

Outdoor 
temperature 
in °F or °C 

Transmitter identification number (only if there is more than one transmitter) 

Outdoor 
reception signal 

Outdoor humidity 
display in RH% 

Summary of Contents for WS-9119U

Page 1: ...t of all its features FEATURES The Intelligent Weather Station WWVB Radio controlled time with manual setting option WWVB reception ON OFF user selectable 12 24 hour time display Time zone option 12 h...

Page 2: ...et up as stated above After all information has been displayed for 15 minutes you can place your sensors outdoors and set your time Important Notes on Set up and Operation The remote temperature humid...

Page 3: ...and stored by the intelligent weather station in the first 3 minutes of power being supplied to it BATTERY CHANGE It is recommended to replace the batteries in all units on an annual basis to ensure o...

Page 4: ...rs signal for all channels Combined with the set key to re detect a new transmitter in displayed channel Stop the alarm during the time alarm or weather alarm ringing Back light on MAX key Display MAX...

Page 5: ...displaying the information for time and date moon phase indoor data weather forecast air pressure air pressure history outdoor data intelligent weather information display Outdoor temperature in F or...

Page 6: ...set to view time as 12 24 hour format The default time display mode is 12h To set to 24h time display 1 Use the MAX or MIN key to toggle the value 2 Confirm with the SET key and enter the Time Zone s...

Page 7: ...month setting The month starts flashing 4 Use the MAX or MIN key to set the month 5 Press the SET key again to confirm and to enter the date setting mode The date starts flashing 6 Use the MAX or MIN...

Page 8: ...o improve The relative air pressure can be manually set to another value within the range of 28 35 to 30 72 inHg 960 1040 hPa or 720 781 mmHg for a better reference 1 The current relative pressure val...

Page 9: ...an be changed when pressing and holding the ALM DATA key for approximately 4 seconds LOW indoor temperature alarm HIGH indoor temperature alarm LOW outdoor temperature alarm HIGH outdoor temperature a...

Page 10: ...setting there are optional sub settings which can be set individually Note The outdoor temperature alarm can only be set for channel 1 transmitter To set the LOW outdoor temperature alarm default OFF...

Page 11: ...ALM DATA key to enter the HIGH indoor humidity alarm setting HIGH INDOOR HUMIDITY ALARM Note Within the HIGH indoor humidity alarm setting there are optional sub settings To set the HIGH indoor humidi...

Page 12: ...flashing 2 Use the MAX or MIN key to set the alarm value 3 Press the SET key to confirm and enter the LOW air pressure alarm setting IV If no HIGH outdoor humidity setting is needed please press the...

Page 13: ...alarm is set to 78 F 25 C and the current value moves to 78 F 25 C the alarm will be activated if it has been enabled Now when the temperature drops to 77 9 F 24 9 C or below and thereafter again inc...

Page 14: ...icon press the ALM DATA key Additionally the trigged alarm value and time will then be displayed briefly for 2 seconds on the bottom part of the weather station LCD If more than one Weather Alarm occu...

Page 15: ...new weather icon in the middle display will be shown Examples of changing weather icons Note After initial set up of the intelligent weather station with the setting of the relative value readings fo...

Page 16: ...ch change 1 2 3 4 5 6 7 8 the odd values are not shown on the vertical axis but can be determined shows in inches of mercury inHg how high or low the past air pressure was as compared to the current o...

Page 17: ...X data will be displayed as following sequences 1 MAX or MIN outdoor temperature data with time and date of recordings Data will flash 2 MAX or MIN outdoor humidity data with time and date of recordin...

Page 18: ...he CH key for 3 seconds outdoor reception signal will show next to channel display To re learn the CURRENT selected channel 1 Press and hold the SET key while pressing the CH key outdoor reception sig...

Page 19: ...nd the air pressure The intelligent weather station will automatically display the following information Minimum temperature of the day Maximum temperature of the day Time frame for the weather foreca...

Page 20: ...will be show when a specific weather event happened that has been calculated by the unique algorithm of the intelligent weather station REMOTE TEMPERATURE HUMIDITY SENSOR 433MHZ RECEPTION CHECK The o...

Page 21: ...s all system units have to be reset see Setting up POSITIONING THE INTELLIGENT WEATHER STATION The intelligent weather station has been designed to hang on a wall or free standing For Free standing Si...

Page 22: ...s this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy SPECIFICATIONS Temperature measuring range Indoor 14 F to 139 8 F with 0 2 F resolution 10 C to 59 9 C with...

Page 23: ...La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of...

Page 24: ...r chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in t...

Reviews: