background image

 

31 

Outdoor Reception  
Signal icon

*

 

Max. and Min. indoor 
temperature records

 

Max. and Min. outdoor 
temperature records

 

• 

Stop the alarm 

 

ALARM key 

• 

Press and hold to enter the alarm setting mode

 

• 

Press the key to switch the alarm ON/ OFF

 

• 

Stop the alarm 

 

 

MIN/MAX RESET key 

• 

Press and hold to reset the MIN/MAX temperature records 

• 

Activate the snooze  

• 

Exit manual setting modes 

 

LCD SCREEN AND SETTINGS:

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 

Time

 

Indoor 

Temperature in °C

Outdoor  
Temperature in °C

 

Weather tendency 

indicator

Weather forecast  
icon

 

Low battery indicator 

(weather station)

Low battery indicator 
(transmitter)

 

Radio controlled time 

reception icon

Alarm icon

Summary of Contents for WS-9137

Page 1: ...It is further featuring a DCF 77 radio controlled clock and alarm function With four easy to use function keys this innovative product is ideal for use in the home or office Instant Transmission is t...

Page 2: ...erature display in degree Celsius C Indoor and outdor temperature with MIN MAX records Manual reset of MIN MAX records 3 weather forecast icons with weather tendency indicator Wireless transmission at...

Page 3: ...Temperature transmitter 2 Within 30 seconds insert the batteries into Weather station see Install and replace batteries in the Weather station Once the batteries are in place all segments of the LCD w...

Page 4: ...This takes typically between 3 5 minutes in good conditions Note Daily DCF reception is done at 02 00 and 03 00 every day If the reception at 03 00 is not successful then at 04 00 and 05 00 and 06 00...

Page 5: ...steps below 1 Remove the battery compartment cover at the back of the transmitter 2 Insert the batteries observing the correct polarity see marking 3 Replace the battery compartment cover on the unit...

Page 6: ...nd has a transmitting range of approximately 1500 km Your radio controlled Weather Station receives this signal and converts it to show the precise time in summer or wintertime The quality of the rece...

Page 7: ...s the Frankfurt transmitter During nighttime the atmospheric disturbances are usually less severe and reception is possible in most cases A single daily reception is adequate to keep the accuracy devi...

Page 8: ...itch the alarm ON OFF Stop the alarm MIN MAX RESET key Press and hold to reset the MIN MAX temperature records Activate the snooze Exit manual setting modes LCD SCREEN AND SETTINGS Time Indoor Tempera...

Page 9: ...ings can be done in the setting mode Time zone Time reception DCF ON OFF Manual time Press the SET key and hold down for a few seconds to enter the setting mode TIME ZONE SETTING The time zone default...

Page 10: ...firm with the SET key and enter the Manual time setting Note If the Time Reception function is turned OFF manually the clock will not attempt any reception of the radio controlled time DCF time as lon...

Page 11: ...is received the manually set time will automatically be replaced by the received time During reception attempts the DCF tower icon will flash If reception has been unsuccessful the DCF tower icon wil...

Page 12: ...on The alarm will stop and re activate after the snooze interval of 10 minutes 2 To stop the alarm completely press any keys other than the MIN MAX RESET key WEATHER FORECAST AND TENDENCY THE WEATHER...

Page 13: ...get worse but not necessarily rainy Note After setting up readings for weather forecasts should be disregarded for the next 12 24 hours This will allow sufficient time for the Weather Station to coll...

Page 14: ...s increasing and the weather is expected to improve but when indicator points downwards the air pressure is dropping and the weather is expected to become worse Taking this into account you will see h...

Page 15: ...S The outdoor temperature and outdoor MIN MAX records are displayed on the last section of the LCD Note The MIN MAX outdoor temperature records range from 40 C to 60 C with 1 C resolution RESETTING TH...

Page 16: ...t least 1 5 to 2 meters away from any interfering sources such as computer monitors or TV sets 2 Avoid positioning the Weather station onto or in the immediate proximity of metal window frames 3 Using...

Page 17: ...ON The Weather Station may be hung onto wall easily or free standing To wall mount Choose a sheltered place Avoid direct rain and sunshine Before wall mounting please check that the outdoor temperatur...

Page 18: ...s and plastic anchors 2 Clip the remote temperature sensor onto the bracket Note Before permanently fixing the transmitter wall base place all units in the desired locations to check that the outdoor...

Page 19: ...t submerge the unit in water Special care shall be taken when handling a damaged LCD display The liquid crystals can be harmful to user s health Do not make any repair attempts to the unit Return them...

Page 20: ...stances Disposal of electronic waste in wild country and or in unauthorized grounds strongly damages the environment Please contact your local or and regional authorities to retrieve the addresses of...

Page 21: ...t is not to be used for medical purposes or for public information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children No par...

Reviews: