background image

 

14

12/24 HOUR TIME DISPLAY SETTING 

 
 
 
 
 
 
 

1. 

After setting time reception ON/OFF, press the SET key, “12h” or “24h” flashes in 
the LCD. (default 12 h) 

2. 

Press the + key to select the “12h” or “24h” display mode. 

3. 

Press the SET again to confirm and to enter the 

“Manual Time setting”

 or exit 

the setting mode by pressing the CH key. 

 

Note:

 When 24h mode display is selected, the calendar format will be date and month 

display. When 12h mode display is selected, the calendar format will be month 
and date display. 

 
MANUAL TIME SETTING 

In case the Weather Station is not able to detect the WWVB-signal (disturbances, 
transmitting distance, etc.), the time can be manually set. The clock will then work as a 
normal Quartz clock. 
 
 
 
To set the clock: 
1. 

The hour and minute digits start flashing in the time display section. 

2. 

Use the + key to adjust the hours and then press SET key to go to the minute 
setting. 

3. 

The minute will be flashing. Press the + key to just the minutes.   

4. 

Confirm with the SET key and enter the 

“Calendar Setting”

 or exit the setting 

mode by pressing the CH key 

 

 flashing 

Minutes (flashing)

Hours (flashing)

Summary of Contents for WS-9620U-IT

Page 1: ...1 Contents Language Page ______________________________________________________________________ English 1 French 74 Spanish...

Page 2: ...trolled Time Manual Settings Weather Forecast and Tendency Display of Indoor Temperature and Humidity Reading Display of Outdoor Temperature and Humidity Reading Display of Indoor Minimum Maximum reco...

Page 3: ...ine Batteries 3 1 Fresh CR2032 3 0V Battery FEATURES Weather Station Removable Stand Battery Compartment Cover Function Keys This product offers INSTANT TRANSMISSION is the state of the art new wirele...

Page 4: ...ttery indicator Table standing Wall mounting SETTING UP When one sensor is used 1 First insert the battery into the thermo hygro sensor see Install and replace batteries in the thermo hygro sensor 2 I...

Page 5: ...1 should then be displayed on the Weather Station Also the signal reception icon will be displayed If this does not happen after 2 minutes the batteries will need to be removed from both units and re...

Page 6: ...s necessary to remove the batteries from all units and follow the set up from step 1 10 Once the remote temperature has been received and displayed on the Weather Station the WWVB time code reception...

Page 7: ...AAA Alkaline batteries To install and replace the batteries please follow the steps below 1 Remove the cover at the back of the Weather Station 2 Insert batteries observing the correct polarity see ma...

Page 8: ...to replace the batteries in all units on an annual basis to ensure optimum accuracy of these units Please participate in the preservation of the environment Return used batteries to an authorized dep...

Page 9: ...ponding to MIN MAX temperature data key To toggle between the current time and current Indoor Temp Humidity display To make adjustment for various settings CH key To toggle between the Outdoor Sensors...

Page 10: ...using 15 different icons featuring Oscar Outlook which change their appearance depending on the air pressure development past air pressure change and the current outdoor temperature Display the weathe...

Page 11: ...www boulder nist gov timefreq htm To listen to the NIST time call 303 499 7111 This number will connect you to an automated time announced at the top of the minute in Coordinated Universal Time which...

Page 12: ...etting or exit the setting mode by pressing the CH key TIME ZONE SETTING The time zone default is EST 5 To set a different time zone 1 The current time zone value starts flashing 2 Use the key to set...

Page 13: ...ock will then work as a normal Quartz clock Default setting is ON 4 The digit ON and the time reception icon will start flashing on the LCD 5 Use the key to turn OFF the time reception function 6 Conf...

Page 14: ...alendar format will be month and date display MANUAL TIME SETTING In case the Weather Station is not able to detect the WWVB signal disturbances transmitting distance etc the time can be manually set...

Page 15: ...also be set manually To do this 1 Using the key set the year The range runs from 2003 to 2029 default is 2006 2 Press the SET key to enter the month setting mode 3 The month digit will be flashing Pre...

Page 16: ...t the setting mode by pressing the CH key WEATHER FORECASTING ICON SENSITIVITY SETTING For locations with rapid changes of weather conditions the threshold can be set to a different level for faster d...

Page 17: ...the centre of LCD which indicates the different forecast weather condition due to air pressure level Sunny Sunny Cloudy or Cloudy Rainy and the current outdoor temperature Temperature value detected b...

Page 18: ...rain the Weather Station will be more accurate compared to use in areas where the weather is stagnant most of the time for example mostly sunny If the Weather Station is moved to another location sig...

Page 19: ...is expected to change For example if the indicator is pointing downwards together with cloudy icons the last noticeable change in the weather was when it was sunny the sunny icon only Therefore the ne...

Page 20: ...MAXIMUM RECORDS 1 In normal display mode press the MIN MAX button five times The maximum indoor temperature and humidity will be shown in the bottom section of LCD Also the time of recording this tem...

Page 21: ...s the SET key once this will reset the currently shown indoor minimum or and maximum data recorded to the current time date temperature and humidity Note The indoor minimum and maximum record is to be...

Page 22: ...min max records of different channels separately The outdoor minimum and maximum record of each channel is to be reset separately 1 In normal display mode press the CH button to select a channel The c...

Page 23: ...sources such as computer monitors or TV sets 2 Avoid positioning the Weather Station onto or in the immediate proximity of metal window frames 3 Using other electrical products such as headphones or...

Page 24: ...red wall leaving the head extended out the by about 5mm 2 Remove the stand from the Weather Station by pulling it away from the base and hang the station onto the screw Remember to ensure that it lock...

Page 25: ...use damage to the unit and give inaccurate forecasts and readings When cleaning the display and casings use a soft damp cloth only Do not use solvents or scouring agents as they may mark the LCD and c...

Page 26: ...idity measuring range 1 to 99 with 1 resolution displays when lower than 1 displays 99 if higher than 99 Indoor temperature checking interval every 15 seconds Indoor humidity checking interval every 2...

Page 27: ...erials for all repairs covered by this warranty If necessary repairs are not covered by this warranty or if a product is examined which is not in need or repair you will be charged for the repairs or...

Page 28: ...DREN S REACH This warranty gives you specific legal rights You may also have other rights specific to your State Some States do no allow the exclusion of consequential or incidental damages therefore...

Page 29: ...emical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the n...

Reviews: