SNOOZE SETTING: 

 
 
 
 
 

 
 
 
 
The snooze time can be set OFF or to a maximum time of 30 minutes (default is 10 
minutes): 
1. 

The snooze time (in minutes) digit will be flashing. Use the CH/ + key to set the 
snooze time (in minutes). Each pressing of the key will increase the snooze time by 5 
minutes. The snooze can also be set OFF when the “OFF” digit is being displayed. 

2. 

Confirm with the SET key and enter the “

ºF/ºC temperature unit setting

” or exit the 

manual setting mode by pressing the SNOOZE/ SUN key. 

 

Note: 

If the snooze time has been set “OFF”, the snooze function will not be activated. 

 

 
 

Flashing 

 

31 

pm

°F/°C TEMPERATURE UNIT SETTING 

 

 
 
 
 
 

 

The default temperature reading is set to °F (degree Fahrenheit). To select °C (degree 
Celsius): 
1. 

The “°F” will be flashing, use the CH/ + key to toggle between “°F” and “°C”. 

2. 

Once the desired temperature unit has been chosen, confirm with the SET key and 
enter the “

Weather Forecast Icon Sensitivity setting

” or exit the setting mode by 

pressing the SNOOZE/ SUN key. 

 

WEATHER FORECASTING ICON SENSITIVITY SETTING

 

For locations with rapid changes of weather conditions, the threshold can be set to a 
different level for faster display of changing weather conditions. 

 
 

 
 
 
 
 

Flashing

 

 

32 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

1. 

The current sensitivity value will start flashing. 

2. 

Using the CH/ + key to set the weather sensitivity level. There are 3 levels of setting: 
1, 2 and 3; level 1 is the most sensitive setting, level 3 is the least sensitive setting 
(default setting is "2").  

3. 

Confirm with the SET key and exit the 

Manual settings

 
 
 
 

Flashing

Flashing 

Summary of Contents for WS-9711U-IT

Page 1: ...7 Warranty 48 FCC Disclaimer 51 INVENTORY OF CONTENTS 1 Wireless Temperature Station WS 9711U IT 2 Wireless Temperature Transmitter TX29U IT 3 Instruction Manual INSTANT TRANSMISSION is the state of t...

Page 2: ...rolled time code reception is automatically started This takes typically between 3 5 minutes in good conditions If after 10 minutes the WWVB time has not been received press the SET key to manually en...

Page 3: ...unit close to a window and or point its front or back towards the Fort Collins Colorado transmitter During nighttime the atmospheric disturbances are usually less severe and reception is possible in...

Page 4: ...The LCD screen is split into 5 sections displaying the information for time date weather forecast indoors and outdoors 15 When the signal from the transmitter is successfully received by the Temperat...

Page 5: ...s to normal operating mode Note If no buttons are pressed within approximately 15 seconds while in any setting option the unit will return to normal operating mode LCD contrast setting Time zone setti...

Page 6: ...will be date and month display When 12h mode display is selected the calendar format will be month and date display MANUAL TIME SETTING In case the Weather Station is not able to detect the WWVB signa...

Page 7: ...obile Kentucky LEX Lexington Oklahoma OKC Oklahoma City TUL Tulsa Arkansas LIT Little Rock Louisiana NEW New Orleans SHV Shreveport Oregon MFR Medford PDX Portland Arizona PHX Phoenix Massachusetts BO...

Page 8: ...setting or exit the manual setting mode by pressing the SNOOZE SUN key Note If the snooze time has been set OFF the snooze function will not be activated Flashing 31 pm F C TEMPERATURE UNIT SETTING Th...

Page 9: ...32 F 36 For every sudden or significant change in the air pressure the weather icons will update accordingly to represent the change in weather If the icons do not change then it means either the air...

Page 10: ...r is used 39 DISPLAY OF INDOOR MAXIMUM AND MINIMUM RECORDS 1 In normal display mode press the MIN MAX button three times The maximum indoor temperature and humidity will be shown Also the date and tim...

Page 11: ...eck the following items 1 The distance of the Weather Station or transmitter should be at least 5 to 6 5 feet away from any interfering sources such as computer monitors or TV sets 2 Avoid positioning...

Page 12: ...erature measuring range Indoor 14 1 F to 139 8 F with 0 2 F resolution 9 9 C to 59 9 C with 0 1 C resolution OF L displayed if outside this range Outdoor 39 8 F to 139 8 F with 0 2 F resolution 39 9 C...

Page 13: ...ive a signal due to any source of interference This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed 50 installation no...

Reviews: