48
displayed on the Weather Clock. If this does not happen after 3 minutes, the batteries
will need to be removed from both units and reset from step 1.
4.
In order to ensure sufficient 868 MHz transmission however, this should under good
conditions be a distance no more than 100 meters between the final position of the
Weather Clock and the transmitter (see notes on “Positioning” and “868 MHz
Reception”).
5.
Once the remote temperature has been received and displayed on the Weather Clock,
the DCF time (radio controlled time) code reception is automatically started. This
takes typically between 3-5 minutes in good conditions. If after 10 minutes, the DCF
time has not been received, press the SET key to manually enter a time initially.
When more than one transmitter is used
1.
User shall remove all the batteries from the Weather Clock and transmitters and wait
for 60 seconds if setting has been done with one transmitter before.
2.
Insert the batteries to the first transmitter.
3.
Within 25 seconds of powering up the first transmitter, insert the batteries to the
Weather Clock. Once the batteries are in place, all segments of the LCD will light up
briefly. Following time as 0:00 and the Weather man icon will be displayed. If they are
not shown in LCD after 60 seconds, remove the batteries and wait for at least 60
seconds before reinserting them.
4.
The outdoor temperature from the first transmitter (channel 1) should then be
displayed on the Weather Clock. Also, the signal reception icon will be displayed. If
this does not happen after 2 minutes, the batteries will need to be removed from both
units and reset from step 1.