ARM/DISARM TEMPERATURE ALERTS 

 
Setting the temperature alerts is one step. Arming them is a 
second step. Press and release the 

TEMP ALERTS

 button to 

toggle between the alerts Outdoor HI/Outdoor LOW/Indoor 
HI/Indoor LOW. 
  

 

Press the 

 button to arm the alert. 

 

Press the 

 button to disarm the 

alert.  

 

ALERT BELL ICON appears when armed.                                  

TEMPERATURE TREND ICONS 

 
The temperature (2°F/1°C) and 
humidity (3% RH) trend indicators 
update every 30 minutes or less.  
The arrows indicate that the 
temperature has risen, fallen or 
stayed steady over the past three hours. 

VIEW/RESET MIN/MAX VALUES 

 
The station automatically resets minimum and maximum values 
daily at midnight (12:00 AM).  

 

 

Press the 

 button to view minimum values

.

    

 

Hold the 

 button to manually reset

 

minimum values

.

   

  

 

 

Press the 

 button to view maximum values

.

  

 

Hold the 

 button to manually reset maximum values

.

   

HEAT INDEX/DEWPOINT 

 

 

Press the 

HEAT/DEW

 button once to view Heat Index.  

 

Press the 

HEAT/DEW

 button twice to view Dew Point. 

SEARCH FOR OUTDOOR SENSOR 

  

 

Hold the 

HEAT/DEW

 button to search for the outdoor sensor.  

 

The strength signal icon will animate until the sensor signal is 
received or for 3 minutes if no signal available.  
 

Summary of Contents for 308-1711BL

Page 1: ... WEATHER STATION Table of Contents INITIAL SETUP 2 LCD FEATURES 3 BUTTON Functions 3 HEAT DEW SENSOR SEARCH 3 TIME DATE SETTINGS 3 MIN TEMP ALERT OFF 4 TEMP ALERTS 4 MAX TEMP ALERT ON 4 TIME ALARM SNOOZE 4 SET TIME DATE ETC 5 SET TIME ALARM 5 ACTIVATE DEACTIVATE TIME ALARM 6 SNOOZE 6 OUTDOOR TEMPERATURE ALERTS 6 ...

Page 2: ...ENSOR 7 MOON PHASE 8 POSITION THE WEATHER STATION 8 POSITION OUTDOOR SENSOR 8 CARE AND MAINTENANCE 8 SPECIFICATIONS 9 WARRANTY AND SUPPORT INFORMATION 9 FCC STATEMENT 10 INITIAL SETUP Step 1 Insert 2 new AA batteries not included into the TX141TH Av2 sensor Observe the correct polarity Step 2 Insert 2 new AA Alkaline batteries not included into the station Observe the correct polarity ...

Page 3: ...er 3 minutes remove the batteries and start from step 1 LCD FEATURES BUTTON Functions HEAT DEW SENSOR SEARCH Normal Display Press once for Heat Index Press twice for Dew Point Hold to search for Outdoor sensor TIME DATE SETTINGS Normal Display Hold for 3 seconds to set time calendar etc Time Calendar Alarm Indoor Temp Humidity with Trend Temperature Alerts ON OFF Outdoor Temp Humidity with Trend H...

Page 4: ... High Alert Outdoor Low Alert Indoor High Alert and Indoor Low Alert Hold to enter Alert setting MAX TEMP ALERT ON Setting Modes Press to increase the values during setting Hold to quickly adjust values Normal Display Press to view maximum temperatures Hold 2 seconds to clear maximum temperature memories Temperature Alert Press to arm alerts TIME ALARM SNOOZE Normal Display Press once to show alar...

Page 5: ...nth 3 Date 4 12 24 Hour 5 Hour 6 Minutes 7 Fahrenheit Celsius 1 Year 2 Month 3 Date 4 12Hr 24Hr Time 5 Hour 6 Minutes 7 Fahrenheit Celsius SET TIME ALARM Setting and activating time alarms are separate actions 1 Hold the TIME ALARM button to enter alarm set mode 2 Press the or buttons to adjust the values 3 Press the TIME ALARM button to confirm move to the next item Hours Minutes Press the TIME D...

Page 6: ...y button except TIME ALARM to stop alarm for one day Note The alarm is crescendo sound The alarm sounds for two minutes and then shut off completely OUTDOOR TEMPERATURE ALERTS Setting the temperature alerts is one step Arming them is a second step 1 Hold the TEMP ALERTS button until the station beeps 2 The temperature alert value will blink in set mode 3 Press the or buttons to adjust the values 4...

Page 7: ...ows indicate that the temperature has risen fallen or stayed steady over the past three hours VIEW RESET MIN MAX VALUES The station automatically resets minimum and maximum values daily at midnight 12 00 AM Press the button to view minimum values Hold the button to manually reset minimum values Press the button to view maximum values Hold the button to manually reset maximum values HEAT INDEX DEWP...

Page 8: ...rete and large metal objects can reduce the range POSITION OUTDOOR SENSOR Mount the outdoor sensor on a north facing wall or in any well shaded area Under an eave or deck rail is preferred The maximum transmitting range to the weather station is over 300 feet 91 meters in open air not including walls CARE AND MAINTENANCE Do not mix old and new batteries Do not mix Alkaline Standard Lithium or Rech...

Page 9: ... over 24 months when using reputable batteries Dimensions Weather station 5 40 L x 1 68 W x 4 40 H 137 2 mm L x 42 8 mm W x 111 8 mm H TX141TH Av2 Sensor 1 57 x 0 82 x 5 11 40 x 20 8 x 129 8mm WARRANTY AND SUPPORT INFORMATION La Crosse Technology Ltd provides a 1 year limited time warranty from date of purchase on this product relating to manufacturing defects in materials workmanship Before retur...

Page 10: ...uipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device must not be co located or operating in conjunction with any other antenna or transmitter Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interf...

Reviews: