Hardware description 

 

66E electronic board without bolt switch, RTC and EEPROM. 

Can drive solenoid (motor option scheduled for next release). 

Connectors to keypad, alarm box and solenoid. 

Configuration can be done via keypad or PC. 

 

Keypad connector 

 

Standard 4 wires connector to keypad, LED, buzzer and emergency battery pads. 

Keypad may include a TAG reader to allow use of serial connection to PC or other devices. 

 

TAG reader connection to serial adapter 

 

Serial connection specifications are: 1'200bauds, no parity, 8 data bits, 1 stop bit. PC and other serial devices may 
be connected to setup the lock and the get audit file.  

Alarm box connector 

 

Standard 4 wires connector to external battery, silent alarm output and remote input.Also used to connect Reset Box 

to initiate factory reset. 

Silent alarm output 

 

When silent alarm mode selected, code entered with last digit plus one will activate this output during 1.5s.  

Remote input 

 

When closed to ground, this input will either deny solenoid activation or override time delay. Selection done by PC 
software.  

Solenoid / motor connector 

 

2 wires connector to solenoid (motor scheduled for next release, selection mode must be defined as procedure to 

activate motor like forward / backward timing). 

Solenoid is activated during 3s. 

A built in battery measure detects battery low condition. 

Summary of Contents for 39E

Page 1: ..._______________________________________________3 Lock states _____________________________________________________________4 Pre setup mode___________________________________________________________ 4...

Page 2: ...specifications are 1 200bauds no parity 8 data bits 1 stop bit PC and other serial devices may be connected to setup the lock and the get audit file Alarm box connector Standard 4 wires connector to...

Page 3: ...lay enabled LED flashes at two seconds intervals Open window is indicated by LED then buzzer at 1 seconds intervals alternately once LED once beep Battery low warning If battery low 6V during solenoid...

Page 4: ...anager function 8 Choose how many digits for manager and users codes Select standard mode without additional features Install users manager function 1 Install all users you need with default codes Del...

Page 5: ...t digit until double beep Enter special function number 0 9 Double beep if valid triple beep if not Open procedures To open Standard mode Enter code If time delay enabled wait open window Enter code a...

Page 6: ...if user blocked Enter new code Enter code again to confirm Double beep if correct triple beep if confirmation error Notes Manager only When enrolled he can install only users that were not blocked by...

Page 7: ...mission LED is still on a during search of audit beginning into memory Notes Manager only Audit file is automatically printed at each power up except in pre setup mode Audit printing may be stopped by...

Page 8: ...y and only if not enrolled his code was never changed Manager cannot choose dual code mode if no user installed nor active If code length is modified users codes are deleted and manager code is set to...

Reviews: