39E Operating instructions
Page
2 / 8
──────────────────────────────────────────────────────────────
SW V1.01
11.09.2005
La Gard Latin America - 741 Shotgun Rd. – Sunrise Florida – 33351 – USA
Tel. +1 954 476 5574 – Fax. + 7 954 476 5576 – Email: info@lagardlat.com
Hardware description
66E electronic board without bolt switch, RTC and EEPROM.
Can drive solenoid (motor option scheduled for next release).
Connectors to keypad, alarm box and solenoid.
Configuration can be done via keypad or PC.
Keypad connector
Standard 4 wires connector to keypad, LED, buzzer and emergency battery pads.
Keypad may include a TAG reader to allow use of serial connection to PC or other devices.
TAG reader connection to serial adapter
Serial connection specifications are: 1'200bauds, no parity, 8 data bits, 1 stop bit. PC and other serial devices may
be connected to setup the lock and the get audit file.
Alarm box connector
Standard 4 wires connector to external battery, silent alarm output and remote input.Also used to connect Reset Box
to initiate factory reset.
Silent alarm output
When silent alarm mode selected, code entered with last digit plus one will activate this output during 1.5s.
Remote input
When closed to ground, this input will either deny solenoid activation or override time delay. Selection done by PC
software.
Solenoid / motor connector
2 wires connector to solenoid (motor scheduled for next release, selection mode must be defined as procedure to
activate motor like forward / backward timing).
Solenoid is activated during 3s.
A built in battery measure detects battery low condition.