39E Operating instructions
Page
3 / 8
──────────────────────────────────────────────────────────────
SW V1.01
11.09.2005
La Gard Latin America - 741 Shotgun Rd. – Sunrise Florida – 33351 – USA
Tel. +1 954 476 5574 – Fax. + 7 954 476 5576 – Email: info@lagardlat.com
Features
39E software is based on 37E, with motor driver and remote override.
Codes & users
Up to ten codes:
•
One manager
(ID = 0): can open, changes his code, manage users, print audit, setup configuration, change
time delay values. Before changing his code for this first time, manager deleting user code will in fact block it.
Once his code is changed, cannot modify configuration nor install users that are blocked.
•
Up to 9 users
(ID = 1 - 9): each user can open and changes his code.
Codes length programmable from 4 to 9 digits long.New codes are rejected when less than 2 digits are different
from existing codes.
Time delay
Time delay programmable from 0 (no time delay) to 99 minutes. Open window from 1 to 19 minutes.
During time delay enabled LED flashes at two seconds intervals. Open window is indicated by LED then buzzer at 1
seconds intervals alternately (once LED, once beep).
Battery low warning
If battery low (< 6V) during solenoid activation, multiple beeps.
Time penalty
When entering code, a time penalty of 5 minutes will be started after the 4
th
consecutive wrong code entered.
During time penalty, LED flashes at 10s interval, no access possible to lock.
Any key pressed during time penalty emits a triple beep.
After time penalty, two consecutive wrong codes will start it again.
Programmable features
Additional features can be individually selected by manager or PC Setup software:
•
Time delay override
: user #9 overrides time delay and opens.
•
Dual code
: two codes needed to access / open.
•
Silent alarm
: last digit of code +1 activates silent alarm when dialing to open or to enter special functions.
Audit
On board non volatile memory records up to 63 last events, including user ID and action.
Audit file is sent to serial interface at each power-up and upon request of manager, using special function #7.
Audit file can not be deleted.